Abstract <p>Advanced additive manufacturing capabilities have enabled a transformational ability to create sophisticated cellular structures using diverse materials. By altering the topology of the unit cell, the mechanical behavior, such as the stress-strain response during compression, can be modulated. Nevertheless, identifying a printable topology within an enormous design space that would precisely deliver the targeted nonlinear material response is challenging. We propose a data-driven generative framework based on a conditional variational autoencoder (cVAE) architecture that can inverse design the cellular structure based on the intended nonlinear stress-strain response. Trained on a dataset of structure-property pairs, the cVAE learns a compact and expressive latent space that enables efficient mapping from targets to feasible geometries. Two inference modes are explored: (1) decoder-only generation, which enables the exploration of diverse designs conditioned solely on the desired mechanical response, and (2) encoder-decoder generation, which further allows for the incorporation of desired topologies, ensuring the generated structure conforms to both mechanical properties and to desired-topology constraints. The results demonstrate that the model can generate structurally plausible and mechanically accurate designs, with the predicted stress-strain curves closely matching the targets. Even under joint conditioning, the model effectively balances geometric fidelity and functional performance.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Inverse design of cellular structures with the targeted nonlinear mechanical response

  • Sushan Nakarmi,
  • Nitin P. Daphalapurkar,
  • Kwan-Soo Lee,
  • Jihyeon Kim,
  • Jeffery A. Leiding,
  • Dana M. Dattelbaum,
  • Darby J. Luscher

摘要

Abstract

Advanced additive manufacturing capabilities have enabled a transformational ability to create sophisticated cellular structures using diverse materials. By altering the topology of the unit cell, the mechanical behavior, such as the stress-strain response during compression, can be modulated. Nevertheless, identifying a printable topology within an enormous design space that would precisely deliver the targeted nonlinear material response is challenging. We propose a data-driven generative framework based on a conditional variational autoencoder (cVAE) architecture that can inverse design the cellular structure based on the intended nonlinear stress-strain response. Trained on a dataset of structure-property pairs, the cVAE learns a compact and expressive latent space that enables efficient mapping from targets to feasible geometries. Two inference modes are explored: (1) decoder-only generation, which enables the exploration of diverse designs conditioned solely on the desired mechanical response, and (2) encoder-decoder generation, which further allows for the incorporation of desired topologies, ensuring the generated structure conforms to both mechanical properties and to desired-topology constraints. The results demonstrate that the model can generate structurally plausible and mechanically accurate designs, with the predicted stress-strain curves closely matching the targets. Even under joint conditioning, the model effectively balances geometric fidelity and functional performance.