<p>Constant power load (CPL) is a representation of dynamic loads such as power converters and electric motor drives to the DC-DC converter. Precise voltage regulation is necessary for such a combination of loads in a DC microgrid setup. In contrast to typical resistive loads, these loads exhibit negative impedance characteristics, which can cause instability in the DC microgrid system. The proposed adaptive backstepping control methodology effectively solves stability problems while yielding a smooth and fast response of the output voltage and inductor current to changes in resistive load and CPL combination. The success of the proposed method is confirmed by extensive real-time experiments carried out on the prototype of 120<i>W</i> converter using the dSpace DS1104 platform. Additionally, to demonstrate the strength of the proposed technique, a thorough comparison is made with the systematically designed cascade-proportional-integral (PI) and the sliding mode based control systems, which clearly indicate the proposed control is found to be <InlineEquation ID="IEq1"> <EquationSource Format="TEX">\(46\%\)</EquationSource> </InlineEquation> and <InlineEquation ID="IEq2"> <EquationSource Format="TEX">\(60\%\)</EquationSource> </InlineEquation> faster compared to cascade PI and sliding mode control methods respectively. Thus showcasing the potential of proposed control technique for real-time CPL applications.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Adaptive control of DC-DC power converter: design and experimental investigation with constant power load

  • Tousif Khan Nizami,
  • Sasank Das Gangula,
  • Ramanjaneya Reddy Udumula,
  • Arghya Chakravarty,
  • Mrutyunjaya Mangaraj,
  • Fareed Ahmad,
  • Arigela Satya Veerendra

摘要

Constant power load (CPL) is a representation of dynamic loads such as power converters and electric motor drives to the DC-DC converter. Precise voltage regulation is necessary for such a combination of loads in a DC microgrid setup. In contrast to typical resistive loads, these loads exhibit negative impedance characteristics, which can cause instability in the DC microgrid system. The proposed adaptive backstepping control methodology effectively solves stability problems while yielding a smooth and fast response of the output voltage and inductor current to changes in resistive load and CPL combination. The success of the proposed method is confirmed by extensive real-time experiments carried out on the prototype of 120W converter using the dSpace DS1104 platform. Additionally, to demonstrate the strength of the proposed technique, a thorough comparison is made with the systematically designed cascade-proportional-integral (PI) and the sliding mode based control systems, which clearly indicate the proposed control is found to be \(46\%\) and \(60\%\) faster compared to cascade PI and sliding mode control methods respectively. Thus showcasing the potential of proposed control technique for real-time CPL applications.