<p><sup>18</sup>Fluorine (<sup>18</sup>F) labeled inhibitors of fibroblast activation protein (<sup>18</sup>F-FAPI) PET/CT is an emerging molecular imaging technique suitable for patients with breast cancer (BC). However, some patients may not tolerate the long waiting time after injection, making it crucial to assess whether early imaging can provide sufficient clinical diagnostic information. In this prospective study, 40 patients with suspected BC underwent dual-phase <sup>18</sup>F-FAPI-04 PET/CT at ~ 10 min (early) and ~ 60 min (late) post-injection. The diagnostic performance of both protocols was compared in differentiating benign from malignant lesions. A total of 51 breast lesions were detected, and SUVmax and lesion-to-background ratio (LBR) were obtained by outlining ROIs. After the PET/CT scan, all lesions underwent tissue biopsy, with 36 being BC and 15 being benign breast lesions (BBL). The results showed a significant difference in SUVmax between early and late imaging (<i>p</i> = 0.001), but no significant difference in LBR (<i>p</i> = 0.456). The <sup>18</sup>F-FAPI-04 uptake in the BC group was significantly higher than in the BBL group. The cutoff values for SUVmax were 3.62 for early imaging and 4.12 for late imaging, while the cutoff values for LBR were 4.42 for early imaging and 4.34 for late imaging. At the optimal cutoff values, early imaging with SUVmax achieved the highest diagnostic performance, with an AUC of 1.00, and both sensitivity and specificity of 100%. The AUC for LBR was 0.93, with a sensitivity of 86.1% and specificity of 86.7%. No significant difference in diagnostic performance was found between early and late imaging (DeLong test; SUVmax <i>p</i> = 0.48 and LBR <i>p</i> = 0.25). Our findings indicate that early <sup>18</sup>F-FAPI-04 PET/CT imaging offers diagnostic accuracy comparable to late imaging while significantly reducing acquisition time, supporting its potential as a practical alternative in clinical practice.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

A prospective comparison of early versus late 18F-FAPI−04 PET/CT imaging for breast cancer diagnosis

  • Zonglin Li,
  • Guohong Lin,
  • Kaiwen Luo,
  • Xiangru Li,
  • Futian Hu,
  • Zheng Zhao,
  • Xiaoting Huang,
  • Yiming Wei,
  • Weiqiang Huang,
  • Tingting Zhang,
  • Shidong Lian

摘要

18Fluorine (18F) labeled inhibitors of fibroblast activation protein (18F-FAPI) PET/CT is an emerging molecular imaging technique suitable for patients with breast cancer (BC). However, some patients may not tolerate the long waiting time after injection, making it crucial to assess whether early imaging can provide sufficient clinical diagnostic information. In this prospective study, 40 patients with suspected BC underwent dual-phase 18F-FAPI-04 PET/CT at ~ 10 min (early) and ~ 60 min (late) post-injection. The diagnostic performance of both protocols was compared in differentiating benign from malignant lesions. A total of 51 breast lesions were detected, and SUVmax and lesion-to-background ratio (LBR) were obtained by outlining ROIs. After the PET/CT scan, all lesions underwent tissue biopsy, with 36 being BC and 15 being benign breast lesions (BBL). The results showed a significant difference in SUVmax between early and late imaging (p = 0.001), but no significant difference in LBR (p = 0.456). The 18F-FAPI-04 uptake in the BC group was significantly higher than in the BBL group. The cutoff values for SUVmax were 3.62 for early imaging and 4.12 for late imaging, while the cutoff values for LBR were 4.42 for early imaging and 4.34 for late imaging. At the optimal cutoff values, early imaging with SUVmax achieved the highest diagnostic performance, with an AUC of 1.00, and both sensitivity and specificity of 100%. The AUC for LBR was 0.93, with a sensitivity of 86.1% and specificity of 86.7%. No significant difference in diagnostic performance was found between early and late imaging (DeLong test; SUVmax p = 0.48 and LBR p = 0.25). Our findings indicate that early 18F-FAPI-04 PET/CT imaging offers diagnostic accuracy comparable to late imaging while significantly reducing acquisition time, supporting its potential as a practical alternative in clinical practice.