<p>Data from wearable devices collected in free-living settings, and labelled with physical activity behaviours compatible with health research, are essential for both validating existing wearable-based measurement approaches and developing novel machine learning approaches. One common way of obtaining these labels relies on laborious human annotation of sequences of images captured by body-worn cameras. The aim of this study was to investigate whether open-source vision-language models could accurately annotate activity intensity classes in wearable camera-based validation studies, thereby reducing the annotation burden. We compared the performance of three vision language models and two discriminative models on two free-living validation studies with 161 and 111 participants, collected in Oxfordshire, United Kingdom and Sichuan, China, respectively, using the Autographer (OMG Life, defunct) wearable camera. We found that the best open-source vision-language model (VLM) and fine-tuned discriminative model (DM) achieved comparable performance when predicting sedentary behaviour from single images on unseen participants in the Oxfordshire study; median F<sub>1</sub>-scores: VLM = 0.89 (0.84, 0.92), DM = 0.91 (0.86, 0.95). Performance declined for light [VLM = 0.60 (0.56, 0.67), DM = 0.70 (0.63, 0.79)], and moderate-to-vigorous intensity physical activity [VLM = 0.66 (0.53, 0.85); DM = 0.72 (0.58, 0.84)]. When applied to the external Sichuan study, performance fell across all intensity categories, with median Cohen’s <i>κ</i> scores falling from 0.54 (0.49, 0.64) to 0.26 (0.15, 0.37) for the VLM, and from 0.67 (0.60, 0.74) to 0.19 (0.10, 0.30) for the DM. Freely available computer vision models could help annotate sedentary behaviour, typically the most prevalent activity of daily living, from wearable camera images within similar populations to seen data, reducing the annotation burden when using cameras as the source of ground-truth.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Reducing annotation burden in physical activity research using vision language models

  • Abram Schönfeldt,
  • Benjamin Maylor,
  • Xiaofang Chen,
  • Ronald Clark,
  • Aiden Doherty

摘要

Data from wearable devices collected in free-living settings, and labelled with physical activity behaviours compatible with health research, are essential for both validating existing wearable-based measurement approaches and developing novel machine learning approaches. One common way of obtaining these labels relies on laborious human annotation of sequences of images captured by body-worn cameras. The aim of this study was to investigate whether open-source vision-language models could accurately annotate activity intensity classes in wearable camera-based validation studies, thereby reducing the annotation burden. We compared the performance of three vision language models and two discriminative models on two free-living validation studies with 161 and 111 participants, collected in Oxfordshire, United Kingdom and Sichuan, China, respectively, using the Autographer (OMG Life, defunct) wearable camera. We found that the best open-source vision-language model (VLM) and fine-tuned discriminative model (DM) achieved comparable performance when predicting sedentary behaviour from single images on unseen participants in the Oxfordshire study; median F1-scores: VLM = 0.89 (0.84, 0.92), DM = 0.91 (0.86, 0.95). Performance declined for light [VLM = 0.60 (0.56, 0.67), DM = 0.70 (0.63, 0.79)], and moderate-to-vigorous intensity physical activity [VLM = 0.66 (0.53, 0.85); DM = 0.72 (0.58, 0.84)]. When applied to the external Sichuan study, performance fell across all intensity categories, with median Cohen’s κ scores falling from 0.54 (0.49, 0.64) to 0.26 (0.15, 0.37) for the VLM, and from 0.67 (0.60, 0.74) to 0.19 (0.10, 0.30) for the DM. Freely available computer vision models could help annotate sedentary behaviour, typically the most prevalent activity of daily living, from wearable camera images within similar populations to seen data, reducing the annotation burden when using cameras as the source of ground-truth.