<p>Herein, cellulose acetate membrane modified with polyethylene terephthalate derived MIL-101(Fe) (PET-MIL-101(Fe)) was used as an extraction phase for the direct immersion-thin film microextraction method (DI-TFME) of neonicotinoid insecticides in water samples. The quantitative analysis of clothianidin, imidacloprid, thiacloprid and thiamethoxam was carried out using high-pressure liquid chromatography (HPLC-DAD). The morphological and structural characteristics of the materials were studied using transmission electron microscopy (TEM), X-ray diffraction analysis (XRD), and energy dispersive X-ray spectrometry (EDX). Under optimum conditions, acceptable analytical performance for the developed DI-TFME/HPLC-DAD method was attained. The linearity of the method ranged from 0.04 to 500&#xa0;µg/L with R<sup>2</sup> ranging from 0.9981 to 0.9989. The detection limits, quantification limits and relative standard deviation (%RSD) of the DI-TFME/HPLC-DAD method were in the range of 0.013–0.016&#xa0;µg/L, 0.043–0.053&#xa0;µg/L and 1.2–3.9%, respectively. The method was applied in the analysis of real water samples, and the spiking recoveries of the target analytes were 95.6–102%, 91.2–98.6% and 79.2‒98.7% for river water, effluent and influent samples, respectively, with %RSDs ranging from 1.8 to 4.8%. These findings demonstrated that the developed DI-TFME/HPLC-DAD method had high precision, accuracy, sensitivity and enrichment factor (73–88). The DI-TFME/HPLC-DAD method proved sustainable for the simultaneous quantification of trace neonicotinoid insecticides in real samples.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Incorporating PET-MIL-101(Fe) within cellulose acetate membrane for thin film microextraction of neonicotinoid insecticides in water

  • Silindokuhle Jakavula,
  • Neliswa Mpayipheli,
  • Azile Nqombolo,
  • Jianwei Ren,
  • Philiswa Nosizo Nomngongo

摘要

Herein, cellulose acetate membrane modified with polyethylene terephthalate derived MIL-101(Fe) (PET-MIL-101(Fe)) was used as an extraction phase for the direct immersion-thin film microextraction method (DI-TFME) of neonicotinoid insecticides in water samples. The quantitative analysis of clothianidin, imidacloprid, thiacloprid and thiamethoxam was carried out using high-pressure liquid chromatography (HPLC-DAD). The morphological and structural characteristics of the materials were studied using transmission electron microscopy (TEM), X-ray diffraction analysis (XRD), and energy dispersive X-ray spectrometry (EDX). Under optimum conditions, acceptable analytical performance for the developed DI-TFME/HPLC-DAD method was attained. The linearity of the method ranged from 0.04 to 500 µg/L with R2 ranging from 0.9981 to 0.9989. The detection limits, quantification limits and relative standard deviation (%RSD) of the DI-TFME/HPLC-DAD method were in the range of 0.013–0.016 µg/L, 0.043–0.053 µg/L and 1.2–3.9%, respectively. The method was applied in the analysis of real water samples, and the spiking recoveries of the target analytes were 95.6–102%, 91.2–98.6% and 79.2‒98.7% for river water, effluent and influent samples, respectively, with %RSDs ranging from 1.8 to 4.8%. These findings demonstrated that the developed DI-TFME/HPLC-DAD method had high precision, accuracy, sensitivity and enrichment factor (73–88). The DI-TFME/HPLC-DAD method proved sustainable for the simultaneous quantification of trace neonicotinoid insecticides in real samples.