<p>Dynamic optical coherence tomography (dOCT) enables high-resolution, label-free 3D tissue imaging with functional contrast, offering a potential advancement in kidney transplant viability assessment. Currently, no widely accepted non-invasive method provides an objective evaluation of transplant viability, as conventional imaging lacks the resolution to assess microvascular integrity and cellular dynamics. However, the clinical use of available dOCT systems is limited by prolonged imaging times that hinder clear visualization of tissue dynamics. To address these challenges, this paper presents a swept-source 3.2&#xa0;MHz-OCT system for dynamic, high-speed, extended-area imaging. The system integrates an optimized inter-volume scan protocol and a micrometer-precision linear robot, enabling extended‑scale tissue imaging over an area of about 2.6 × 2.6&#xa0;mm<sup>2</sup>. Using freshly excised porcine kidney tissue, we demonstrate recent advancements and challenges in MHz-dOCT for kidney imaging. Identified anatomical features are thoroughly examined, compared across resolutions, and validated through histology to assess the system’s clinical potential.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Label-free volumetric imaging of porcine kidney tissue over extended areas using dynamic MHz-OCT

  • Sazgar Burhan,
  • Madita Göb,
  • Mario Pieper,
  • Tjalfe Laedtke,
  • Thorge Grahl,
  • Michael Münter,
  • Hinnerk Schulz-Hildebrandt,
  • Gereon Hüttmann,
  • Peter König,
  • Robert Huber

摘要

Dynamic optical coherence tomography (dOCT) enables high-resolution, label-free 3D tissue imaging with functional contrast, offering a potential advancement in kidney transplant viability assessment. Currently, no widely accepted non-invasive method provides an objective evaluation of transplant viability, as conventional imaging lacks the resolution to assess microvascular integrity and cellular dynamics. However, the clinical use of available dOCT systems is limited by prolonged imaging times that hinder clear visualization of tissue dynamics. To address these challenges, this paper presents a swept-source 3.2 MHz-OCT system for dynamic, high-speed, extended-area imaging. The system integrates an optimized inter-volume scan protocol and a micrometer-precision linear robot, enabling extended‑scale tissue imaging over an area of about 2.6 × 2.6 mm2. Using freshly excised porcine kidney tissue, we demonstrate recent advancements and challenges in MHz-dOCT for kidney imaging. Identified anatomical features are thoroughly examined, compared across resolutions, and validated through histology to assess the system’s clinical potential.