<p>In this paper, a small size multistubs resonator based flexible wearable antenna is demonstrated for dual-band operation. The proposed antenna is composed of vertically aligned multistubs resonator, a 50&#xa0;Ω microstrip feed and a defected ground structure (DGS). This configuration of antenna resonates at 2.4 and 5.8&#xa0;GHz Industrial, Scientific, and Medical (ISM) sub-6&#xa0;GHz bands. It has a small footprint of 32 × 17 × 0.508&#xa0;mm<sup>3</sup> (0.256 λ<sub><i>L</i></sub> × 0.136 λ<sub><i>L</i></sub> × 0.004 λ<sub><i>L</i></sub> at <i>f</i><sub><i>L</i></sub> = 2.4&#xa0;GHz), with measured reflection coefficient magnitudes (|S<sub>11</sub>|) of − 15.81&#xa0;dB with bandwidth of 280&#xa0;MHz (2.3–2.58&#xa0;GHz) and − 33.06&#xa0;dB with bandwidth of 580&#xa0;MHz (5.42–6&#xa0;GHz) at 2.425 and 5.72&#xa0;GHz, respectively. Moreover, it has bidirectional and omnidirectional radiation features due to DGS with a measured peak gains of 1.317&#xa0;dBi (2.425&#xa0;GHz) and 4.759&#xa0;dBi (5.72&#xa0;GHz). This study also explored a widespread investigation on a parametric study, specific absorption rate (SAR), diverse bending conditions and its interaction with diverse on-body circumstances (by placement on the chest, hand, and leg). The SAR values are 1.29&#xa0;W/kg (1&#xa0;g) and 0.88&#xa0;W/kg (10&#xa0;g) at 2.43&#xa0;GHz whereas at 5.8&#xa0;GHz, the SAR values are 0.507&#xa0;W/kg (1&#xa0;g) and 0.257&#xa0;W/kg (10&#xa0;g), which well within SAR safe limits. The antenna adhere the effective robustness, stable performance during bending deformations and on-body scenarios which validated the antenna effectiveness for wearable sub-6&#xa0;GHz ISM band applications.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Design of a compact multistubs resonator based dual-band flexible wearable antenna with low SAR for sub-6 GHz ISM applications

  • Gaurav Kumar Soni,
  • Dinesh Yadav,
  • Ashok Kumar,
  • Amit Rathi,
  • Swati Varun Yadav

摘要

In this paper, a small size multistubs resonator based flexible wearable antenna is demonstrated for dual-band operation. The proposed antenna is composed of vertically aligned multistubs resonator, a 50 Ω microstrip feed and a defected ground structure (DGS). This configuration of antenna resonates at 2.4 and 5.8 GHz Industrial, Scientific, and Medical (ISM) sub-6 GHz bands. It has a small footprint of 32 × 17 × 0.508 mm3 (0.256 λL × 0.136 λL × 0.004 λL at fL = 2.4 GHz), with measured reflection coefficient magnitudes (|S11|) of − 15.81 dB with bandwidth of 280 MHz (2.3–2.58 GHz) and − 33.06 dB with bandwidth of 580 MHz (5.42–6 GHz) at 2.425 and 5.72 GHz, respectively. Moreover, it has bidirectional and omnidirectional radiation features due to DGS with a measured peak gains of 1.317 dBi (2.425 GHz) and 4.759 dBi (5.72 GHz). This study also explored a widespread investigation on a parametric study, specific absorption rate (SAR), diverse bending conditions and its interaction with diverse on-body circumstances (by placement on the chest, hand, and leg). The SAR values are 1.29 W/kg (1 g) and 0.88 W/kg (10 g) at 2.43 GHz whereas at 5.8 GHz, the SAR values are 0.507 W/kg (1 g) and 0.257 W/kg (10 g), which well within SAR safe limits. The antenna adhere the effective robustness, stable performance during bending deformations and on-body scenarios which validated the antenna effectiveness for wearable sub-6 GHz ISM band applications.