<p>The performance of fans and pumps is pivotal to the efficiency and responsiveness of the engine cooling system. In this study, a joint simulation model incorporating a detailed engine cooling system was developed and calibrated using vehicle road cycle tests, and the predictive capabilities of four different machine learning models for water pump and fan speeds were systematically evaluated. Calibration results indicate that the simulated speeds deviate from experimental values by less than 2%, accurately reflecting real-world driving conditions. Moreover, the instantaneous fuel consumption closely mirrors the experimental data, and the error in cumulative fuel consumption under the NEDC is limited to 1.4%. The simulation outcomes for the cooling system remain within a 5% error margin, thus meeting the designated calibration criteria. Among the water pump speed prediction models, the SVR model demonstrates the highest accuracy and reliability, achieving a test mean square error (MSE) of 0.03986. In contrast, for fan speed prediction, the RF model delivers superior performance with a test MSE of 0.00052, aligning closely with experimental observations without overfitting. Consequently, the RF model proves to be the most accurate and reliable approach for fan speed prediction. These findings provide a solid theoretical basis and a robust modeling foundation for intelligent management of engine cooling systems.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Performance prediction of electronic fan and water pump of engine cooling system based on joint simulation and machine learning

  • Yujin Zou,
  • Renwang Li,
  • Honghua Pan,
  • Xiao Sun,
  • Jun Fu

摘要

The performance of fans and pumps is pivotal to the efficiency and responsiveness of the engine cooling system. In this study, a joint simulation model incorporating a detailed engine cooling system was developed and calibrated using vehicle road cycle tests, and the predictive capabilities of four different machine learning models for water pump and fan speeds were systematically evaluated. Calibration results indicate that the simulated speeds deviate from experimental values by less than 2%, accurately reflecting real-world driving conditions. Moreover, the instantaneous fuel consumption closely mirrors the experimental data, and the error in cumulative fuel consumption under the NEDC is limited to 1.4%. The simulation outcomes for the cooling system remain within a 5% error margin, thus meeting the designated calibration criteria. Among the water pump speed prediction models, the SVR model demonstrates the highest accuracy and reliability, achieving a test mean square error (MSE) of 0.03986. In contrast, for fan speed prediction, the RF model delivers superior performance with a test MSE of 0.00052, aligning closely with experimental observations without overfitting. Consequently, the RF model proves to be the most accurate and reliable approach for fan speed prediction. These findings provide a solid theoretical basis and a robust modeling foundation for intelligent management of engine cooling systems.