<p>Granulomatous mastitis (GM) poses challenges in diagnosis and treatment due to its similarities with other breast diseases like cancer. The comparative study evaluated the efficacy and safety of a vacuum-assisted biopsy device with minimally invasive excisions compared to traditional wide local excisions. The vacuum-assisted biopsy device technique offers benefits such as precise tissue removal, reduced damage to healthy tissue, shorter surgery and recovery times, and lower postoperative complication risks. The study found that the vacuum-assisted biopsy device had comparable efficacy to traditional wide local excision in treating GM with an overall effectiveness rate of 92.9% and a recurrence rate of 9.52%. The vacuum-assisted biopsy device group showed advantages in reduced hospitalization duration (2.83 days vs. 7.52 days), lower costs, and better cosmetic outcomes, with a 100% patient satisfaction rate compared to 80% in the control group. This study fills existing clinical evidence gaps regarding the effectiveness and safety of vacuum-assisted biopsy device in GM treatment. By providing evidence-based guidelines, it aims to assist clinicians in choosing the most appropriate treatment for GM patients, ultimately improving their quality of life and mental well-being. The research contributes valuable insights into GM therapy, potentially revolutionizing treatment approaches and enhancing patient outcomes.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Non-inferiority of minimally invasive rotational cutting in granulomatous mastitis treatment: a comparative trial

  • Fuman Zhang,
  • Chengyi Li,
  • Xinquan Wu,
  • Kali Miao,
  • Zhe Zhang,
  • Jing Zhang

摘要

Granulomatous mastitis (GM) poses challenges in diagnosis and treatment due to its similarities with other breast diseases like cancer. The comparative study evaluated the efficacy and safety of a vacuum-assisted biopsy device with minimally invasive excisions compared to traditional wide local excisions. The vacuum-assisted biopsy device technique offers benefits such as precise tissue removal, reduced damage to healthy tissue, shorter surgery and recovery times, and lower postoperative complication risks. The study found that the vacuum-assisted biopsy device had comparable efficacy to traditional wide local excision in treating GM with an overall effectiveness rate of 92.9% and a recurrence rate of 9.52%. The vacuum-assisted biopsy device group showed advantages in reduced hospitalization duration (2.83 days vs. 7.52 days), lower costs, and better cosmetic outcomes, with a 100% patient satisfaction rate compared to 80% in the control group. This study fills existing clinical evidence gaps regarding the effectiveness and safety of vacuum-assisted biopsy device in GM treatment. By providing evidence-based guidelines, it aims to assist clinicians in choosing the most appropriate treatment for GM patients, ultimately improving their quality of life and mental well-being. The research contributes valuable insights into GM therapy, potentially revolutionizing treatment approaches and enhancing patient outcomes.