错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Enhancing the electrical readout of the spin-dependent recombination current in SiC JFETs for EDMR based magnetometry using a tandem (de-)modulation technique

  • Andreas Gottscholl,
  • Hannes Kraus,
  • Thomas Aichinger,
  • Corey J. Cochrane

摘要

Electrically detected magnetic resonance (EDMR) is a promising method to readout spins in miniaturized devices utilized as quantum magnetometers. However, the sensitivity has remained challenging. In this study, we present a tandem (de-)modulation technique based on a combination of magnetic field and radio frequency modulation. By enabling higher demodulation frequencies to avoid 1/f-noise, enhancing self-calibration capabilities, and eliminating background signals by 3 orders of magnitude, this technique represents a significant advancement in the field of EDMR-based sensors. This novel approach paves the way for EDMR being the ideal candidate for ultra-sensitive magnetometry at ambient conditions without any optical components, which brings it one step closer to a chip-based quantum sensor for future applications.