<p>Noninvasive electromechanical assessment of cardiovascular function is emerging as a cost-effective method for diagnosis of heart failure and arterial diseases, and for telemedical monitoring of blood pressure and neural disorders. It encompasses simultaneous acquisition of electrocardiographic, phonocardiographic, arterial-pulse, chest-vibration, bioimpedance and other waveforms. The phases and amplitudes of these waveforms are used for construction of disease biomarkers. The procedure includes corrections of biomarker values to daily variation and excursions of heart rate. However, datasets that enable a systematic study of the effects of heart rate on mechanical waveforms are currently not available. Here, we describe SensSmartTech - the first dataset of multiparametric cardiovascular signals systematically measured in a large span of heart rates from 52 to 182 beats per minute, achieved by running on a treadmill. Besides providing the data for biomarker correction, the dataset enables new insights into the cardio-respiratory and electro-mechanical couplings in the cardiovascular system.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Synchronous post-exercise electrocardiogram, phonocardiogram, photoplethysmograms and seismocardiogram

  • Aleksandar Lazović,
  • Vladimir Atanasoski,
  • Predrag Tadić,
  • Natalija Djordjević,
  • Maša Tiosavljević,
  • Marija D. Ivanović,
  • Ljupčo Hadžievski,
  • Arsen Ristić,
  • Vladan Vukčević,
  • Jovana Petrović

摘要

Noninvasive electromechanical assessment of cardiovascular function is emerging as a cost-effective method for diagnosis of heart failure and arterial diseases, and for telemedical monitoring of blood pressure and neural disorders. It encompasses simultaneous acquisition of electrocardiographic, phonocardiographic, arterial-pulse, chest-vibration, bioimpedance and other waveforms. The phases and amplitudes of these waveforms are used for construction of disease biomarkers. The procedure includes corrections of biomarker values to daily variation and excursions of heart rate. However, datasets that enable a systematic study of the effects of heart rate on mechanical waveforms are currently not available. Here, we describe SensSmartTech - the first dataset of multiparametric cardiovascular signals systematically measured in a large span of heart rates from 52 to 182 beats per minute, achieved by running on a treadmill. Besides providing the data for biomarker correction, the dataset enables new insights into the cardio-respiratory and electro-mechanical couplings in the cardiovascular system.