<p>We share long term, continuous measurements of soil radon emanations in Italy acquired from 2009 to 2021 by the Italian Radon mOnitoring Network (IRON). The radon concentrations were measured at 62 stations and consist of 621 720 single measurements. Employed detectors are both in-house prototypes (LUCAS) and commercial devices (AER by Algade©), suitably calibrated at INGV radionuclide laboratory. In addiction to radon concentration, most stations acquire internal temperature, while a subset of them also record relative humidity. When available, all these data series are provided along with radon time series and consist of 1 320 710 local temperature and humidity data. The presented dataset allows monitoring variations in radon emissions on multiple time scales, using different analysis techniques. Potential investigations include the effect of environmental parameters/conditions on radon emissions, the study of the impact on such emissions of transient signals like those associated with seismic and volcanic preparation processes and fluid migration dynamics as well as analyses of risk for human health, related to prolonged exposure to radon gas accumulated in confined spaces.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Soil Radon Time Series from the Italian Radon Monitoring Network (IRON)

  • Antonio Piersanti,
  • Valentina Cannelli,
  • Gianfranco Galli,
  • Gaia Soldati,
  • Monica Piochi,
  • Raffaella Silvia Iovine,
  • Alessandro Pignatelli,
  • Veronica Vignoli,
  • Giulia Romoli,
  • Matteo Albano,
  • Andrea Antonioli,
  • Maria Grazia Ciaccio,
  • Antonino D’Alessandro,
  • Gianfilippo De Astis,
  • Stefano Farroni,
  • Anna Figlioli,
  • Carlo Giunchi,
  • Marco Massa,
  • Marco Moro,
  • Adriano Nardi,
  • Michele Saroli,
  • Marcello Silvestri,
  • Salvatore Scudero,
  • Massimiliano Vallocchia

摘要

We share long term, continuous measurements of soil radon emanations in Italy acquired from 2009 to 2021 by the Italian Radon mOnitoring Network (IRON). The radon concentrations were measured at 62 stations and consist of 621 720 single measurements. Employed detectors are both in-house prototypes (LUCAS) and commercial devices (AER by Algade©), suitably calibrated at INGV radionuclide laboratory. In addiction to radon concentration, most stations acquire internal temperature, while a subset of them also record relative humidity. When available, all these data series are provided along with radon time series and consist of 1 320 710 local temperature and humidity data. The presented dataset allows monitoring variations in radon emissions on multiple time scales, using different analysis techniques. Potential investigations include the effect of environmental parameters/conditions on radon emissions, the study of the impact on such emissions of transient signals like those associated with seismic and volcanic preparation processes and fluid migration dynamics as well as analyses of risk for human health, related to prolonged exposure to radon gas accumulated in confined spaces.