<p>Functional near-infrared spectroscopy (fNIRS) is a promising neuroimaging method owing to its non-invasive nature and adaptability to real-world settings. However, fNIRS signal quality is sensitive to individual differences in biophysical factors such as hair and skin characteristics, which can considerably impact the absorption and scattering of near-infrared light. If not properly addressed, these factors risk biasing fNIRS research by disproportionately affecting signal quality across diverse populations. Here we quantify the impact of hair properties and skin pigmentation, as well as head size, sex and age, on signal quality in <i>n</i> = 115 individuals. We provide recommendations for fNIRS researchers, including a suggested metadata table and guidance for cap and optode configurations, hair management techniques and strategies to optimize data collection across varied participants. This research will help to guide future hardware advances and methodological standards to overcome barriers to inclusivity in fNIRS studies.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Quantifying the impact of hair and skin characteristics on fNIRS signal quality for enhanced inclusivity

  • Meryem A. Yücel,
  • Jessica E. Anderson,
  • De’Ja Rogers,
  • Parisa Hajirahimi,
  • Parya Farzam,
  • Yuanyuan Gao,
  • Rini I. Kaplan,
  • Emily J. Braun,
  • Nishaat Mukadam,
  • Sudan Duwadi,
  • Laura Carlton,
  • David Beeler,
  • Lindsay K. Butler,
  • Erin Carpenter,
  • Jaimie Girnis,
  • John Wilson,
  • Vaibhav Tripathi,
  • Yiwen Zhang,
  • Bettina Sorger,
  • Alexander von Lühmann,
  • David C. Somers,
  • Alice Cronin-Golomb,
  • Swathi Kiran,
  • Terry D. Ellis,
  • David A. Boas

摘要

Functional near-infrared spectroscopy (fNIRS) is a promising neuroimaging method owing to its non-invasive nature and adaptability to real-world settings. However, fNIRS signal quality is sensitive to individual differences in biophysical factors such as hair and skin characteristics, which can considerably impact the absorption and scattering of near-infrared light. If not properly addressed, these factors risk biasing fNIRS research by disproportionately affecting signal quality across diverse populations. Here we quantify the impact of hair properties and skin pigmentation, as well as head size, sex and age, on signal quality in n = 115 individuals. We provide recommendations for fNIRS researchers, including a suggested metadata table and guidance for cap and optode configurations, hair management techniques and strategies to optimize data collection across varied participants. This research will help to guide future hardware advances and methodological standards to overcome barriers to inclusivity in fNIRS studies.