<p>Single-photon spectroscopy utilizing single-pixel binary detectors, often statistically recovers “high-dimension” spectral information from “low-dimension” photon-counting signals with ultra-high sensitivity. Nevertheless, it has been a significantly long-standing challenge to achieve either high-speed or high-resolution spectral measurements under photon-deficient scenarios. This study proposes single-photon dual-comb ghost imaging spectroscopy (DC-GIS), which utilizes a mode-resolved dual-comb matrix to interrogate the sample and directly calculates the high-resolution spectrum from photon-counting signals in milliseconds through ghost-imaging method. The concept of single-photon DC-GIS has been examined by measuring the vib-rotational transitions of acetylene with a resolution of 125 MHz and a measurement time of 6.4 ms, and ultra-long distance (125 km) fiber sensing based on phase-shifted fiber Bragg grating with an ultra-high sensitivity of 0.5 με with femtowatt-level power per comb line. This approach brings the high-speed and high-resolution spectroscopy to the cutting-edge research of photon-scarce scenarios.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Single-photon dual-comb ghost imaging spectroscopy

  • Daowang Peng,
  • Liang Mei,
  • Zhenfeng Gong,
  • Zhong Zuo,
  • Zhiwei Liu,
  • Yuanfeng Di,
  • Xu Liu,
  • Chenglin Gu,
  • Wenxue Li,
  • Guofeng Yan

摘要

Single-photon spectroscopy utilizing single-pixel binary detectors, often statistically recovers “high-dimension” spectral information from “low-dimension” photon-counting signals with ultra-high sensitivity. Nevertheless, it has been a significantly long-standing challenge to achieve either high-speed or high-resolution spectral measurements under photon-deficient scenarios. This study proposes single-photon dual-comb ghost imaging spectroscopy (DC-GIS), which utilizes a mode-resolved dual-comb matrix to interrogate the sample and directly calculates the high-resolution spectrum from photon-counting signals in milliseconds through ghost-imaging method. The concept of single-photon DC-GIS has been examined by measuring the vib-rotational transitions of acetylene with a resolution of 125 MHz and a measurement time of 6.4 ms, and ultra-long distance (125 km) fiber sensing based on phase-shifted fiber Bragg grating with an ultra-high sensitivity of 0.5 με with femtowatt-level power per comb line. This approach brings the high-speed and high-resolution spectroscopy to the cutting-edge research of photon-scarce scenarios.