错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Posterior corneal stability after small incision lenticule extraction with different optical zones

  • Xueying Cheng,
  • Yu Zhao,
  • Dan Fu,
  • Xingtao Zhou,
  • Ying Gao,
  • Zhiqiang Yu

摘要

Background

To assess the changes in the posterior corneal surface following small incision lenticule extraction (SMILE) with different optical zones.

Methods

In this retrospective study, 106 eyes of 106 patients who underwent SMILE were recruited 3 years after the procedure. Eyes were divided into two groups according to the size of the surgical optical zone: group A (52 eyes, ≤6.2 mm) and group B (54 eyes, ≥6.5 mm). Posterior central elevation (PCE) and 12 other points at 45°, 135°, 225° and 315° with distances of 1 mm, 2 mm and 3 mm from the centre were recorded from Pentacam.

Results

No iatrogenic keratectasia was identified, and eyes in the two groups showed comparable visual results. The overall trend in posterior corneal elevation changes was consistent for both groups. PCE decreased significantly from 1.33 ± 2.32 to 0.75 ± 2.41 in group A (P = 0.024) and from 0.87 ± 2.61 to 0.06 ± 2.74 in group B (P = 0.003). All points in the central 2 mm region in both groups were reduced postoperatively. In the 4 mm and 6 mm corneal annulus, almost all points at 225°and 315° showed backward displacement, with the most prominent change occurring at 315° in the 6 mm annulus (P < 0.001), indicating no forward protrusion in the inferior area.

Conclusions

No forward protrusion in the posterior corneal surface was observed 3 years after SMILE with different optical zones. Comprehensive preoperative measurements are essential for ensuring corneal stability and avoiding iatrogenic keratectasia.