<p>The detection and interpretation of brain signals are crucial for advancing brain-computer interface (BCI) technologies. Local field potential (LFP) signals, reflecting synchronized neuronal ensemble activity, offer insights into coordinated neural function. In this study, we present a miniaturized tunneling magnetoresistance (TMR)-based neural magnetrode optimized for in vivo LFP magnetic recording. The magnetrode achieves a magnetoresistance ratio (145%) and low-field sensitivity (16.59 %/mT), while maintaining low detection limits of 4.8 nT/√Hz at 1 Hz and 140 pT/√Hz at 1 kHz. Noise analysis revealed that reducing bias current and applying high-frequency AC excitation significantly suppress low-frequency 1/f noise. In vitro simulations validate LFP reconstruction capability, and in vivo experiments demonstrate a strong correlation (<i>r</i> = 0.857 ± 0.031, <i>p</i> &lt; 0.01) between magnetic and electrical LFPs. Furthermore, in vitro durability tests in artificial cerebrospinal fluid demonstrated exceptional stability, with negligible signal drift (&lt;0.4% variation in TMR ratio) over a 7-day period. This work establishes the TMR-based magnetrode emerges as a new potential tool for neural interface technologies, with implications real-time BCI and neuropathology research.</p><p></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

An advanced TMR sensor-based magnetrode for in vivo LFP magnetic field recording

  • Yi Wang,
  • Jiahui Luo,
  • Chenglong Zhang,
  • Zhenhu Jin,
  • Mixia Wang,
  • Zhaojie Xu,
  • Xinxia Cai,
  • Jiamin Chen

摘要

The detection and interpretation of brain signals are crucial for advancing brain-computer interface (BCI) technologies. Local field potential (LFP) signals, reflecting synchronized neuronal ensemble activity, offer insights into coordinated neural function. In this study, we present a miniaturized tunneling magnetoresistance (TMR)-based neural magnetrode optimized for in vivo LFP magnetic recording. The magnetrode achieves a magnetoresistance ratio (145%) and low-field sensitivity (16.59 %/mT), while maintaining low detection limits of 4.8 nT/√Hz at 1 Hz and 140 pT/√Hz at 1 kHz. Noise analysis revealed that reducing bias current and applying high-frequency AC excitation significantly suppress low-frequency 1/f noise. In vitro simulations validate LFP reconstruction capability, and in vivo experiments demonstrate a strong correlation (r = 0.857 ± 0.031, p < 0.01) between magnetic and electrical LFPs. Furthermore, in vitro durability tests in artificial cerebrospinal fluid demonstrated exceptional stability, with negligible signal drift (<0.4% variation in TMR ratio) over a 7-day period. This work establishes the TMR-based magnetrode emerges as a new potential tool for neural interface technologies, with implications real-time BCI and neuropathology research.