错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

High vs low CPAP strategy with aerosolized calfactant in preterm infants with respiratory distress syndrome

  • D. C. Kaluarachchi,
  • E. Gerday,
  • T. Bahr,
  • H. A. Zapata,
  • M. R. Lasarev,
  • S. O. Guthrie,
  • S. Minton

摘要

Background

Optimal CPAP strategy to prevent CPAP failure defined as need for endotracheal intubation is unknown.

Objective

To evaluate the risk of CPAP failure in infants treated with high vs low CPAP strategy while receiving aerosolized calfactant in the AERO-02 clinical trial and AERO-03 expanded access program.

Methods

Infants born between 29 0/7 to 36 6/7 weeks were included. Comparisons were made between low and high CPAP groups (Low, 4–7 cm H2O; High, 8–10 cm H2O).

Results

CPAP failure and pneumothorax were not different between the groups. Odds of CPAP failure were not different after adjustment for baseline characteristics (OR = 0.61; 95% CI: 0.29, 1.24).

Conclusion

We found no difference in CPAP failure among infants who received aerosolized calfactant that were treated with high vs low CPAP strategy. Efficacy of high CPAP strategy with aerosolized surfactant treatment needs to be evaluated in future studies.