Does Robotic Assistance Help with Bone Preservation in Total Knee Replacement?
摘要
Introduction
This research paper investigates whether robotic total knee replacement (TKR) reduces bone resection compared to conventional TKR. While TKR is a successful procedure, revision surgery remains a challenge with up to 8.3% of all knee replacement procedures requiring revisions.
Materials and methodsThe study retrospectively analyzed the tibial polyethylene inserts used and bone cuts made in 157 primary TKRs performed by a single surgeon. The results show that 93.3% of robotic TKRs used the base size tibial polyethylene of 9 mm, and the average distal femoral cut was 7.4 mm and the average tibial cut was 6.4 mm, with the minimum being 3 mm.
ConclusionThe study suggests that robotic TKR reduces bone resection compared to conventional TKR.