Purpose <p>This study aimed to evaluate the use of an acrylic plate to stabilize hand positioning during EOS imaging to improve the Thumb Ossification Composite Index (TOCI) assessment in pediatric patients with idiopathic scoliosis. The goal was to implement a more efficient workflow with reduced radiation exposure, while maintaining diagnostic accuracy without relying on conventional hand radiography.</p> Methods <p>This prospective study involved 84 patients, aged 7–13&#xa0;years, divided into two groups: Group A (42 patients without acrylic plate stabilization) and Group B (42 patients with acrylic plate stabilization). Both groups underwent whole-spine imaging using the EOS system, and the reliability of EOS imaging in the evaluation of TOCI was compared with that of conventional hand radiography. Statistical analysis was used to assess inter- and intra-rater reliabilities using Cohen’s weighted kappa.</p> Results <p>Group A had an average inter-rater reliability of 0.826, whereas Group B showed a significantly higher reliability of 0.905 (<i>p</i> = 0.0127). The intra-rater reliability for Group A ranged from 0.747 to 0.748, whereas for Group B, it was 0.931 (<i>p</i> = 0.0017).</p> Conclusion <p>EOS imaging with an acrylic plate is a reliable, low-radiation alternative to traditional radiography for TOCI assessment in scoliosis management. Although further improvements are required to match conventional methods in terms of accuracy, the reduced radiation exposure offers significant benefits to pediatric patients.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Improving the reliability of the thumb ossification composite index in patients with scoliosis using EOS imaging with acrylic plates

  • Arihisa Shimura,
  • Hidetoshi Nojiri,
  • Takatoshi Okuda,
  • Hiromitsu Takano,
  • Shota Tamagawa,
  • Juri Teramoto,
  • Hisashi Ishibashi,
  • Yuta Sugawara,
  • Kazuki Nakai,
  • Muneaki Ishijima

摘要

Purpose

This study aimed to evaluate the use of an acrylic plate to stabilize hand positioning during EOS imaging to improve the Thumb Ossification Composite Index (TOCI) assessment in pediatric patients with idiopathic scoliosis. The goal was to implement a more efficient workflow with reduced radiation exposure, while maintaining diagnostic accuracy without relying on conventional hand radiography.

Methods

This prospective study involved 84 patients, aged 7–13 years, divided into two groups: Group A (42 patients without acrylic plate stabilization) and Group B (42 patients with acrylic plate stabilization). Both groups underwent whole-spine imaging using the EOS system, and the reliability of EOS imaging in the evaluation of TOCI was compared with that of conventional hand radiography. Statistical analysis was used to assess inter- and intra-rater reliabilities using Cohen’s weighted kappa.

Results

Group A had an average inter-rater reliability of 0.826, whereas Group B showed a significantly higher reliability of 0.905 (p = 0.0127). The intra-rater reliability for Group A ranged from 0.747 to 0.748, whereas for Group B, it was 0.931 (p = 0.0017).

Conclusion

EOS imaging with an acrylic plate is a reliable, low-radiation alternative to traditional radiography for TOCI assessment in scoliosis management. Although further improvements are required to match conventional methods in terms of accuracy, the reduced radiation exposure offers significant benefits to pediatric patients.