3D CT modeling demonstrates the anatomic feasibility of S1AI screw trajectory for spinopelvic fixation in neuromuscular scoliosis

  • Xochitl M. Bryson,
  • Nicole S. Pham,
  • Ian Hollyer,
  • Serena Hu,
  • Lawrence A. Rinsky,
  • John S. Vorhies

摘要

Purpose

In patients with neuromuscular scoliosis undergoing posterior spinal fusion, the S2 alar iliac (S2AI) screw trajectory is a safe and effective method of lumbopelvic fixation but can lead to implant prominence. Here we use 3D CT modeling to demonstrate the anatomic feasibility of the S1 alar iliac screw (S1AI) compared to the S2AI trajectory in patients with neuromuscular scoliosis.

Methods

This retrospective study used CT scans of 14 patients with spinal deformity to create 3D spinal reconstructions and model the insertional anatomy, max length, screw diameter, and potential for implant prominence between 28 S2AI and 28 S1AI screw trajectories.

Results

Patients had a mean age of 14.42 (range 8–21), coronal cobb angle of 85° (range 54–141), and pelvic obliquity of 28° (range 4–51). The maximum length and diameter of both screw trajectories were similar. S1AI screws were, on average, 6.3 ± 5 mm less prominent than S2AI screws relative to the iliac crests. S2AI screws were feasible in all patients, while in two patients, posterior elements of the lumbar spine would interfere with S1AI screw insertion.

Conclusion

In this cohort of patients with neuromuscular scoliosis, we demonstrate that the S1AI trajectory offers comparable screw length and diameter to an S2AI screw with less implant prominence. An S1AI screw, however, may not be feasible in some patients due to interference from the posterior elements of the lumbar spine.