Analysis of Pull-out Tests for Resin-Grouted Rib Bolts
摘要
Resin-grouted rib bolts serve as a crucial means of stabilizing spalling of coal ribs in underground coal mines. A comprehensive investigation into their efficacy was undertaken by a collaborative effort between the National Institute for Occupational Safety and Health (NIOSH) and Missouri University of Science and Technology (MST). This study involved pull-out tests of rib bolts in multiple locations, including six coal mines and the NIOSH research mine. A total of seventy-three (73) pull-out tests were conducted for rib bolts installed at different rotation speeds and a wide range of anchorage lengths, ranging from a short encapsulation length of 0.305 m to a fully grouted encapsulation length of 1.524 m. The test findings indicate that when short encapsulation bolts are installed at high rotation speeds, their anchorage capacity is significantly reduced, leading to failure at the bolt-grout interface. Conversely, when these bolts are installed at lower rotation speeds, they exhibit greater capacity, with failure occurring at a higher anchorage load equivalent to the yield load of steel rebar. Regardless of the rotational speeds used during installation of the fully grouted bolts, they consistently experienced failure at the ultimate load of the steel rebar. Most of the tests carried out on partially grouted bolts with anchorage lengths of 0.610–0.914 m have shown behavior patterns like the fully grouted bolts, although exhibiting reduced stiffness. The outcomes of this research offer a profound insight into the ways in which resin-grouted bolts enhance the stability of coal mine ribs.