Changing some of the parameters impacting ejector flow performance in thermal power plant condensers
摘要
This study focuses on ejector systems that employ air as the secondary fluid that is suctioned by high-pressure steam as the primary fluid. The multiple steady-state flow regimes that exist inside the ejector have been examined in order to improve ejector performance using vacuum optimum settings and extensive simulations. After thorough analysis, the ejector’s throat length, divergence length, and motive steam pressure were changed. The results of the analysis using finite element method (FEM) Computational Fluid Dynamics were deemed adequate. The relationship between throat length, divergence length, and motive steam pressure was found to have an impact on both suction pressure and ejector performance. Both the throat length (0.3413 m) and the length of the divergence (0.836 m) are determined after evaluating the ejector and making the required changes to obtain a sufficient vacuum. The ideal motive steam pressure for ejector motion is 10 bar. Researchers found that a vacuum of -1.025 bar was preferable to either the standard ejector or other vacuums.