<p>Bundled bars, also known as bundled reinforcement, involve grouping multiple steel bars together to form a single unit, which is then embedded within concrete structures. The comprehensive understand of the behavior of bundled bars in reinforced concrete structures is yet to be explored. This study investigates the behavior of bundled reinforcement bars in concrete beams, aiming to assess their influence on structural performance. A series of experiments were conducted, including pullout tests on bundled bars and flexural and shear tests on concrete beams with and without stirrups. The study evaluated various parameters such as peak load, displacement, ductility, stiffness, and energy absorption capacity for different bundling configurations. Results indicate that bundling enhances the peak load capacity and energy absorption of beams, with minimal impact on displacement and stiffness. However, beams without stirrups exhibit higher stiffness compared to those with stirrups, suggesting a trade-off between shear capacity and structural rigidity. Overall, the findings provide insights into the behavior of bundled reinforcement bars in concrete structures, informing design practices for enhanced structural performance and resilience. Contrary to IS code (IS 456: 2000—Plain and Reinforced Concrete—Code of Practice) recommendations, findings from this study indicate that such recommendations are not essential and could even be counterproductive.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Exploring the Bond, Flexure, and Shear Behaviour of Bundled Bars in Concrete Structures

  • M. Ponni,
  • D. Shobha Rajkumar

摘要

Bundled bars, also known as bundled reinforcement, involve grouping multiple steel bars together to form a single unit, which is then embedded within concrete structures. The comprehensive understand of the behavior of bundled bars in reinforced concrete structures is yet to be explored. This study investigates the behavior of bundled reinforcement bars in concrete beams, aiming to assess their influence on structural performance. A series of experiments were conducted, including pullout tests on bundled bars and flexural and shear tests on concrete beams with and without stirrups. The study evaluated various parameters such as peak load, displacement, ductility, stiffness, and energy absorption capacity for different bundling configurations. Results indicate that bundling enhances the peak load capacity and energy absorption of beams, with minimal impact on displacement and stiffness. However, beams without stirrups exhibit higher stiffness compared to those with stirrups, suggesting a trade-off between shear capacity and structural rigidity. Overall, the findings provide insights into the behavior of bundled reinforcement bars in concrete structures, informing design practices for enhanced structural performance and resilience. Contrary to IS code (IS 456: 2000—Plain and Reinforced Concrete—Code of Practice) recommendations, findings from this study indicate that such recommendations are not essential and could even be counterproductive.