<p>Noninvasive detection of ultra-weak biomagnetic signals is crucial for modern biosensing, but conventional magnetic sensors are fundamentally limited by intrinsic noise. Orthogonal fluxgates (OFGs) enable high signal-to-noise-ratio detection of weak magnetic fields, yet their performance is still constrained by intrinsic 1/f noise and Barkhausen-related magnetic fluctuations. This study reports a low-noise orthogonal fluxgate in which a newly designed magnetic core and circuit mitigate existing noise limitations. The CoP/Ag composite core, featuring an amorphous-nanocrystalline dual phase, is associated with reduced low-frequency magnetic loss and improved noise performance. When integrated with a closed-loop feedback, the sensor achieves a noise floor of 8 pT/√Hz at 1&#xa0;Hz. The sensor enables reliable detection of ultralow-concentration magnetic-bead signals. Alpha-fetoprotein (AFP) was used as a model biomarker in an immunomagnetic bead assay, yielding a linear response from 50&#xa0;fg&#xa0;mL<sup>−1</sup> to 100&#xa0;ng&#xa0;mL<sup>−1</sup> and a detection limit of 50&#xa0;fg&#xa0;mL<sup>−1</sup>, which compares favorably with representative reported AFP magnetic biosensors. OFGs demonstrate strong prospects in biosensing, geomagnetic measurements, and weak field detection. <MediaObject ID="MO6"> <ImageObject Color="Color" FileRef="MediaObjects/40820_2026_2317_Figa_HTML.png" Format="PNG" Height="608" Rendition="HTML" Resolution="300" Type="LinedrawHalftone" Width="767" /> </MediaObject></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Ultralow Noise Orthogonal Fluxgates Enabling Weak Magnetic Field and Biomolecular Detection

  • Xiaofeng Pu,
  • Zhijun Sheng,
  • Zhoulu Yu,
  • Huaidong Li,
  • Xintao Wei,
  • Tao Yang,
  • Qingfang Liu,
  • Guozhi Chai,
  • Xiaolei Liang,
  • Daqiang Gao

摘要

Noninvasive detection of ultra-weak biomagnetic signals is crucial for modern biosensing, but conventional magnetic sensors are fundamentally limited by intrinsic noise. Orthogonal fluxgates (OFGs) enable high signal-to-noise-ratio detection of weak magnetic fields, yet their performance is still constrained by intrinsic 1/f noise and Barkhausen-related magnetic fluctuations. This study reports a low-noise orthogonal fluxgate in which a newly designed magnetic core and circuit mitigate existing noise limitations. The CoP/Ag composite core, featuring an amorphous-nanocrystalline dual phase, is associated with reduced low-frequency magnetic loss and improved noise performance. When integrated with a closed-loop feedback, the sensor achieves a noise floor of 8 pT/√Hz at 1 Hz. The sensor enables reliable detection of ultralow-concentration magnetic-bead signals. Alpha-fetoprotein (AFP) was used as a model biomarker in an immunomagnetic bead assay, yielding a linear response from 50 fg mL−1 to 100 ng mL−1 and a detection limit of 50 fg mL−1, which compares favorably with representative reported AFP magnetic biosensors. OFGs demonstrate strong prospects in biosensing, geomagnetic measurements, and weak field detection.