<p>In 2023, a first-generation prototype of a small-scale marine current turbine was operated in Sequim Bay, Washington (USA) for 141&#xa0;days. The system, referred to as the Turbine Lander, was the product of a laboratory-to-field effort to develop a system that enables enhanced ocean sensing or vehicle recharge in remote, energetic settings. The turbine consists of a vertical-axis, cantilevered rotor <InlineEquation ID="IEq1"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="40722_2025_411_Article_IEq1.gif" Format="GIF" Height="19" Rendition="HTML" Resolution="72" Type="Linedraw" Width="129" /> </InlineMediaObject> <EquationSource Format="TEX">\((1.19~\text {m} \times 0.85~\text {m})\)</EquationSource> <EquationSource Format="MATHML"><math> <mrow> <mo stretchy="false">(</mo> <mn>1.19</mn> <mspace width="3.33333pt" /> <mtext>m</mtext> <mo>×</mo> <mn>0.85</mn> <mspace width="3.33333pt" /> <mtext>m</mtext> <mo stretchy="false">)</mo> </mrow> </math></EquationSource> </InlineEquation> with four foils installed on a gravity foundation. A broader range of constraints including the deployment strategy, site characteristics, and estimated loads, drove the system’s design. This work presents the design, characterization, operation, and post-recovery engineering assessment of the Turbine Lander. Pre-deployment characterization efforts yielded a peak power coefficient of approximately 0.3 for the rotor, although system losses resulted in much lower water-to-wire efficiencies under most operating conditions. The results demonstrate the importance of co-design among key components of the powertrain and control systems to achieve acceptable system efficiency across operating conditions.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Lessons learned from the design and operation of a small-scale cross-flow tidal turbine

  • Christopher Bassett,
  • Paul Gibbs,
  • Harlin Wood,
  • Robert J. Cavagnaro,
  • Ben Cunningham,
  • Jesse Dosher,
  • James Joslin,
  • Brian Polagye

摘要

In 2023, a first-generation prototype of a small-scale marine current turbine was operated in Sequim Bay, Washington (USA) for 141 days. The system, referred to as the Turbine Lander, was the product of a laboratory-to-field effort to develop a system that enables enhanced ocean sensing or vehicle recharge in remote, energetic settings. The turbine consists of a vertical-axis, cantilevered rotor \((1.19~\text {m} \times 0.85~\text {m})\) ( 1.19 m × 0.85 m ) with four foils installed on a gravity foundation. A broader range of constraints including the deployment strategy, site characteristics, and estimated loads, drove the system’s design. This work presents the design, characterization, operation, and post-recovery engineering assessment of the Turbine Lander. Pre-deployment characterization efforts yielded a peak power coefficient of approximately 0.3 for the rotor, although system losses resulted in much lower water-to-wire efficiencies under most operating conditions. The results demonstrate the importance of co-design among key components of the powertrain and control systems to achieve acceptable system efficiency across operating conditions.