<p>We present a comparative computational study of two stabilized Reduced Order Models (ROMs) for the simulation of convection-dominated incompressible flow (Reynolds number of the order of a few thousands). Representative solutions in the parameter space, which includes either time only or time and Reynolds number, are computed with a Finite Volume method and used to generate a reduced basis via Proper Orthogonal Decomposition (POD). Galerkin projection of the Navier–Stokes equations onto the reduced space is used to compute the ROM solution. To ensure computational efficiency, the number of POD modes is truncated and ROM solution accuracy is recovered through two stabilization methods: (i) adding a global constant artificial viscosity to the reduced dimensional model, and (ii) adding a different value of artificial viscosity for the different POD modes. We test the stabilized ROMs for fluid flow in an idealized medical device consisting of a conical convergent, a narrow throat, and a sudden expansion. Both stabilization methods significantly improve the ROM solution accuracy over a standard (non-stabilized) POD-Galerkin model.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Stabilized POD reduced order models for convection-dominated incompressible flows

  • Pierfrancesco Siena,
  • Michele Girfoglio,
  • Annalisa Quaini,
  • Gianluigi Rozza

摘要

We present a comparative computational study of two stabilized Reduced Order Models (ROMs) for the simulation of convection-dominated incompressible flow (Reynolds number of the order of a few thousands). Representative solutions in the parameter space, which includes either time only or time and Reynolds number, are computed with a Finite Volume method and used to generate a reduced basis via Proper Orthogonal Decomposition (POD). Galerkin projection of the Navier–Stokes equations onto the reduced space is used to compute the ROM solution. To ensure computational efficiency, the number of POD modes is truncated and ROM solution accuracy is recovered through two stabilization methods: (i) adding a global constant artificial viscosity to the reduced dimensional model, and (ii) adding a different value of artificial viscosity for the different POD modes. We test the stabilized ROMs for fluid flow in an idealized medical device consisting of a conical convergent, a narrow throat, and a sudden expansion. Both stabilization methods significantly improve the ROM solution accuracy over a standard (non-stabilized) POD-Galerkin model.