<p>Pyroelectric sensors based on pyroelectric effect have a wide range of applications. However, the use of lead-containing materials limits their development. In this paper, Na<sub>0.5</sub>Bi<sub>0.5</sub>TiO<sub>3</sub>-Na<sub>0.5</sub>Bi<sub>4.5</sub>TiO<sub>15</sub>-Mn lead-free pyroelectric ceramics are used as sensitive materials to prepare pyroelectric sensors. Na<sub>0.5</sub>Bi<sub>0.5</sub>TiO<sub>3</sub>-Na<sub>0.5</sub>Bi<sub>4.5</sub>TiO<sub>15</sub>-Mn ceramics can achieve 7.58 × 10<sup>–4</sup> C·m<sup>−2</sup>·K<sup>−1</sup> high-room-temperature pyroelectric coefficient and depolarization temperature of 151&#xa0;°C. Due to the low dielectric constant and loss caused by Mn doping, the high detection rate value of 24.382&#xa0;μPa<sup>−1/2</sup> is obtained. The voltage response rate and specific detection rate of the sensor prepared on this basis can attain the JC-T 2397-2017 (<i>ε</i><sub>r</sub> &gt; 200, tan<i>δ</i> &lt; 5%, <i>T</i><sub>c</sub> &gt; 200, <i>p</i> &gt; 3.50 × 10<sup>–4</sup> C·m<sup>−2</sup>·K<sup>−1</sup>) application standard of pyroelectric infrared detectors. Thermoelectric cooler is proposed to adjust the temperature of the sensor, and its voltage response to human radiation is measured. Harnessing the superior pyroelectric attributes of advanced materials and connectable devices, the nascent thermoelectric–pyroelectric detection method is poised to be a subject of intensive investigation and development.</p> Graphical abstract <p></p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Enhancing pyroelectric detection performance of Na0.5Bi0.5TiO3-based lead-free ceramics via thermoelectric effect

  • Liang-Wei Hu,
  • Wei Cao,
  • Jun-Feng Jin,
  • Xiao-Long Sun,
  • Xiao-Lu Zhu,
  • Wen-Hao Xie,
  • Yue Hou,
  • Zi-Yu Wang,
  • Rui Xiong

摘要

Pyroelectric sensors based on pyroelectric effect have a wide range of applications. However, the use of lead-containing materials limits their development. In this paper, Na0.5Bi0.5TiO3-Na0.5Bi4.5TiO15-Mn lead-free pyroelectric ceramics are used as sensitive materials to prepare pyroelectric sensors. Na0.5Bi0.5TiO3-Na0.5Bi4.5TiO15-Mn ceramics can achieve 7.58 × 10–4 C·m−2·K−1 high-room-temperature pyroelectric coefficient and depolarization temperature of 151 °C. Due to the low dielectric constant and loss caused by Mn doping, the high detection rate value of 24.382 μPa−1/2 is obtained. The voltage response rate and specific detection rate of the sensor prepared on this basis can attain the JC-T 2397-2017 (εr > 200, tanδ < 5%, Tc > 200, p > 3.50 × 10–4 C·m−2·K−1) application standard of pyroelectric infrared detectors. Thermoelectric cooler is proposed to adjust the temperature of the sensor, and its voltage response to human radiation is measured. Harnessing the superior pyroelectric attributes of advanced materials and connectable devices, the nascent thermoelectric–pyroelectric detection method is poised to be a subject of intensive investigation and development.

Graphical abstract