Backgrounds <p>Automated PROMISE (aPROMISE), which is an artificial intelligence-supported software for prostate-specific membrane antigen (PSMA) PET/CT based on PROMISE V2, has demonstrated diagnostic utility with better correspondence rates compared to manual diagnosis. However, previous studies have consistently utilized <sup>18</sup>F-PSMA PET/CT. Therefore, we investigated the diagnostic utility of aPROMISE using both <sup>18</sup>F- and <sup>68</sup>&#xa0;Ga-PSMA PET/CT of Japanese patients with metastatic prostate cancer (mPCa).</p> Materials and methods <p>We retrospectively evaluated 21 PSMA PET/CT images (<sup>68</sup>&#xa0;Ga-PSMA PET/CT: <i>n</i> = 12, <sup>18</sup>F-PSMA PET/CT: <i>n</i> = 9) from 21 patients with mPCa. A single, well-experienced nuclear radiologist performed manual diagnosis following PROMISE V2 and subsequently performed aPROMISE-assisted diagnosis to assess miTNM and details of metastatic sites. We compared the diagnostic time and correspondence rates of miTNM diagnosis between manual and aPROMISE-assisted diagnoses. Additionally, we investigated the differences in diagnostic performance between the two radioisotopes.</p> Results <p>aPROMISE-assisted diagnosis was significantly associated with shorter median diagnostic time compared to manual diagnosis (427&#xa0;s [IQR: 370–834] vs. 1,114&#xa0;s [IQR: 922–1291], <i>p</i> &lt; 0.001). The time reduction with aPROMISE-assisted diagnosis was particularly notable when using <sup>68</sup>&#xa0;Ga-PSMA PET/CT. aPROMISE had high diagnostic accuracy with 100% sensitivity for miT, M1a, and M1b stages. Notably, for M1b stages, aPROMISE achieved 100% sensitivity and specificity, regardless of the type of radioisotope used. However, aPROMISE was misinterpreted in lymph node detection in some cases and missed five visceral metastases (2 adrenal and 3 liver), resulting in lower sensitivity for miM1c stage (63%). In addition to detecting metastatic sites, aPROMISE successfully provided detailed metrics, including the number of metastatic lesions, total metastatic volume, and SUV mean.</p> Conclusions <p>Despite the preliminary nature of the study, aPROMISE-assisted diagnosis significantly reduces diagnostic time and achieves satisfactory accuracy compared to manual diagnosis. While aPROMISE is effective in detecting bone metastases, its limitations in identifying lymph node and visceral metastases must be carefully addressed. This study supports the utility of aPROMISE in Japanese patients with mPCa and underscores the need for further validation in larger cohorts.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Comparison of diagnostic performance between manual diagnosis following PROMISE V2 and aPROMISE utilizing Ga/F-PSMA PET/CT

  • Yuki Enei,
  • Takafumi Yanagisawa,
  • Atsuya Okada,
  • Hidetoshi Kuruma,
  • Chieko Okazaki,
  • Ken Watanabe,
  • Nat P. Lenzo,
  • Takahiro Kimura,
  • Kenta Miki

摘要

Backgrounds

Automated PROMISE (aPROMISE), which is an artificial intelligence-supported software for prostate-specific membrane antigen (PSMA) PET/CT based on PROMISE V2, has demonstrated diagnostic utility with better correspondence rates compared to manual diagnosis. However, previous studies have consistently utilized 18F-PSMA PET/CT. Therefore, we investigated the diagnostic utility of aPROMISE using both 18F- and 68 Ga-PSMA PET/CT of Japanese patients with metastatic prostate cancer (mPCa).

Materials and methods

We retrospectively evaluated 21 PSMA PET/CT images (68 Ga-PSMA PET/CT: n = 12, 18F-PSMA PET/CT: n = 9) from 21 patients with mPCa. A single, well-experienced nuclear radiologist performed manual diagnosis following PROMISE V2 and subsequently performed aPROMISE-assisted diagnosis to assess miTNM and details of metastatic sites. We compared the diagnostic time and correspondence rates of miTNM diagnosis between manual and aPROMISE-assisted diagnoses. Additionally, we investigated the differences in diagnostic performance between the two radioisotopes.

Results

aPROMISE-assisted diagnosis was significantly associated with shorter median diagnostic time compared to manual diagnosis (427 s [IQR: 370–834] vs. 1,114 s [IQR: 922–1291], p < 0.001). The time reduction with aPROMISE-assisted diagnosis was particularly notable when using 68 Ga-PSMA PET/CT. aPROMISE had high diagnostic accuracy with 100% sensitivity for miT, M1a, and M1b stages. Notably, for M1b stages, aPROMISE achieved 100% sensitivity and specificity, regardless of the type of radioisotope used. However, aPROMISE was misinterpreted in lymph node detection in some cases and missed five visceral metastases (2 adrenal and 3 liver), resulting in lower sensitivity for miM1c stage (63%). In addition to detecting metastatic sites, aPROMISE successfully provided detailed metrics, including the number of metastatic lesions, total metastatic volume, and SUV mean.

Conclusions

Despite the preliminary nature of the study, aPROMISE-assisted diagnosis significantly reduces diagnostic time and achieves satisfactory accuracy compared to manual diagnosis. While aPROMISE is effective in detecting bone metastases, its limitations in identifying lymph node and visceral metastases must be carefully addressed. This study supports the utility of aPROMISE in Japanese patients with mPCa and underscores the need for further validation in larger cohorts.