Purpose of Review <p>This retrospective, case controlled, comparative evaluation review of radiation exposure during epidural procedures in interventional pain management assessed variations in radiation exposure based on obesity, race, and gender.</p> Recent Findings <p>Numerous publications have shown increasing radiation exposure based on body mass index (BMI).&#xa0;However, the influence of race and gender have not been studied.</p> <p>A recent study assessing radiation exposure for epidural procedures with mandated 2 views, compared to a single view or optional 2 views, showed an increase in exposure time of 21%, with radiation dose increases of 133%. The influence of obesity, has been studied, but potential influence of race, and gender on radiation exposure for epidural procedures has not been studied.</p> Summary <p>The present review shows a prevalence of total obesity with BMI of 30 or above of 50.9%, with a higher prevalence in patients below the age of 45, female gender, and African Americans. Mean fluoroscopy time and dose increased significantly from 6.9&#xa0;s to 0.925 milligray (mGy) for all epidural procedures for those who are underweight to 10.0&#xa0;s and 6.7 mGy for those with Class 3 obesity above BMI of 40. However, after adjusting for body mass index, no significant differences were noted in race for both fluoroscopy time and radiation dose across multiple epidural procedures. Fluoroscopy time and radiation dose increased in males in cervical interlaminar and lumbar transforaminal procedures.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Influence of Obesity, Race and Gender on Radiation Exposure for Epidural Procedures

  • Laxmaiah Manchikanti,
  • Alan D. Kaye,
  • Mahendra R. Sanapati,
  • Vidyasagar Pampati,
  • Sahar Shekoohi,
  • Joshua A. Hirsch

摘要

Purpose of Review

This retrospective, case controlled, comparative evaluation review of radiation exposure during epidural procedures in interventional pain management assessed variations in radiation exposure based on obesity, race, and gender.

Recent Findings

Numerous publications have shown increasing radiation exposure based on body mass index (BMI). However, the influence of race and gender have not been studied.

A recent study assessing radiation exposure for epidural procedures with mandated 2 views, compared to a single view or optional 2 views, showed an increase in exposure time of 21%, with radiation dose increases of 133%. The influence of obesity, has been studied, but potential influence of race, and gender on radiation exposure for epidural procedures has not been studied.

Summary

The present review shows a prevalence of total obesity with BMI of 30 or above of 50.9%, with a higher prevalence in patients below the age of 45, female gender, and African Americans. Mean fluoroscopy time and dose increased significantly from 6.9 s to 0.925 milligray (mGy) for all epidural procedures for those who are underweight to 10.0 s and 6.7 mGy for those with Class 3 obesity above BMI of 40. However, after adjusting for body mass index, no significant differences were noted in race for both fluoroscopy time and radiation dose across multiple epidural procedures. Fluoroscopy time and radiation dose increased in males in cervical interlaminar and lumbar transforaminal procedures.