<p>In this study, a novel dispersive magnetic solid-phase extraction (DMSPE) method utilizing a magnetite/clinoptilolite zeolite nanocomposite was developed for the extraction and pre-concentration of triptorelin acetate (TA) from aqueous solutions. The pre-concentrated analyte was quantified using high-performance liquid chromatography with ultraviolet detection (HPLC-UV). The magnetic nanocomposite was synthesized and characterized for its structural, morphological, and magnetic properties using field emission scanning electron microscopy (FESEM), powder X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), nitrogen adsorption–desorption isotherms (BET), and vibrating sample magnetometry (VSM). Key parameters affecting extraction efficiency including pH, temperature, extraction and desorption times, sorbent amount, and the type, volume, and concentration of the eluent were systematically investigated and optimized. Method validation was performed under optimal conditions. The calibration curve for TA was linear over the range of 5.0–250.0 ng mL<sup>‒1</sup> with a correlation coefficient of 0.9988. The DMSPE–HPLC-UV method achieved a detection limit of 1.1 ng mL<sup>‒1</sup> and a pre-concentration factor of 100. Its applicability was demonstrated by successfully detecting TA in various urine samples.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

An efficient DMSPE technique based on magnetite/clinoptilolite zeolite nanocomposite for the pre-concentration of triptorelin in urine samples

  • Hossein Abdolmohammad-Zadeh,
  • Hamid Mobedi,
  • Elahe Mobedi

摘要

In this study, a novel dispersive magnetic solid-phase extraction (DMSPE) method utilizing a magnetite/clinoptilolite zeolite nanocomposite was developed for the extraction and pre-concentration of triptorelin acetate (TA) from aqueous solutions. The pre-concentrated analyte was quantified using high-performance liquid chromatography with ultraviolet detection (HPLC-UV). The magnetic nanocomposite was synthesized and characterized for its structural, morphological, and magnetic properties using field emission scanning electron microscopy (FESEM), powder X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), nitrogen adsorption–desorption isotherms (BET), and vibrating sample magnetometry (VSM). Key parameters affecting extraction efficiency including pH, temperature, extraction and desorption times, sorbent amount, and the type, volume, and concentration of the eluent were systematically investigated and optimized. Method validation was performed under optimal conditions. The calibration curve for TA was linear over the range of 5.0–250.0 ng mL‒1 with a correlation coefficient of 0.9988. The DMSPE–HPLC-UV method achieved a detection limit of 1.1 ng mL‒1 and a pre-concentration factor of 100. Its applicability was demonstrated by successfully detecting TA in various urine samples.