<p>Preservatives in sports and energy drinks play a crucial role, especially in maintaining their quality and safety, while caffeine is included mainly in energy drinks as a stimulant to enhance alertness, focus, and physical performance. In this study, a rapid, simple and sensitive RP-HPLC method for simultaneous determination of caffeine, sodium benzoate (SB) and potassium sorbate (PS) in sports and energy drinks was developed. Separation of analytes was achieved using Poroshell 120 EC - C18 (3.0 × 50&#xa0;mm, 2.7&#xa0;µm) analytical column. The best results were obtained by isocratic elution with mobile phase consisting of acetonitrile and phosphate buffer (KH<sub>2</sub>PO<sub>4</sub>/H<sub>3</sub>PO<sub>4</sub>) with pH = 3.8 in volume ratio 85/15 (<i>V/V</i>), flow rate of 1.0&#xa0;mL/min, and a constant column temperature of (25&#xa0;°C). The detection was performed at 230, 260 and 275&#xa0;nm. The developed RP-HPLC method was validated regarding the selectivity/specificity, linearity (<i>R</i><sup>2</sup> ≥ 0.996), accuracy (recoveries between 95.99 and 101.5%), precision (intra-day RSD &lt; 1%), limit of detection (LOD) and limit of quantification (LOQ). All the validation parameters were within the acceptance range. The linearity of the RP-HPLC method was confirmed with <i>R</i><sup>2</sup> values higher than 0.996 in the concentration range of 49.95 - 449.55&#xa0;mg/L for caffeine, 29.97 - 269.73&#xa0;mg/L for SB, and 60.53 - 544.85&#xa0;mg/L for PS. Intra-day repeatability data demonstrated that proposed method was reliable, and it is characterized by high precision (RSD <InlineEquation ID="IEq1"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="11694_2025_3319_Article_IEq1.gif" Format="GIF" Height="15" Rendition="HTML" Resolution="72" Type="Linedraw" Width="19" /> </InlineMediaObject> <EquationSource Format="TEX">\(\le\)</EquationSource> <EquationSource Format="MATHML"><math> <mo>≤</mo> </math></EquationSource> </InlineEquation> 0.49%). The recovery data ranged between 95.99 - 101.50%, indicating excellent recoveries for SB, PS and caffeine by the proposed RP-HPLC method. LODs were 0.015&#xa0;mg/L for caffeine, 0.025&#xa0;mg/L for SB, and 0.018&#xa0;mg/L for PS, while LOQs were 0.083&#xa0;mg/L for SB, 0.059&#xa0;mg/L for PS and 0.049&#xa0;mg/L for caffeine. The proposed method was successfully applied for determination of caffeine, SB and PS in sports and energy drinks.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Development and validation of an RP-HPLC method for the determination of caffeine and preservatives (sodium benzoate and potassium sorbate) in sports and energy drinks

  • Mirjana S. Jankulovska,
  • Simona Stojchevska,
  • Lenche Velkoska-Markovska

摘要

Preservatives in sports and energy drinks play a crucial role, especially in maintaining their quality and safety, while caffeine is included mainly in energy drinks as a stimulant to enhance alertness, focus, and physical performance. In this study, a rapid, simple and sensitive RP-HPLC method for simultaneous determination of caffeine, sodium benzoate (SB) and potassium sorbate (PS) in sports and energy drinks was developed. Separation of analytes was achieved using Poroshell 120 EC - C18 (3.0 × 50 mm, 2.7 µm) analytical column. The best results were obtained by isocratic elution with mobile phase consisting of acetonitrile and phosphate buffer (KH2PO4/H3PO4) with pH = 3.8 in volume ratio 85/15 (V/V), flow rate of 1.0 mL/min, and a constant column temperature of (25 °C). The detection was performed at 230, 260 and 275 nm. The developed RP-HPLC method was validated regarding the selectivity/specificity, linearity (R2 ≥ 0.996), accuracy (recoveries between 95.99 and 101.5%), precision (intra-day RSD < 1%), limit of detection (LOD) and limit of quantification (LOQ). All the validation parameters were within the acceptance range. The linearity of the RP-HPLC method was confirmed with R2 values higher than 0.996 in the concentration range of 49.95 - 449.55 mg/L for caffeine, 29.97 - 269.73 mg/L for SB, and 60.53 - 544.85 mg/L for PS. Intra-day repeatability data demonstrated that proposed method was reliable, and it is characterized by high precision (RSD \(\le\) 0.49%). The recovery data ranged between 95.99 - 101.50%, indicating excellent recoveries for SB, PS and caffeine by the proposed RP-HPLC method. LODs were 0.015 mg/L for caffeine, 0.025 mg/L for SB, and 0.018 mg/L for PS, while LOQs were 0.083 mg/L for SB, 0.059 mg/L for PS and 0.049 mg/L for caffeine. The proposed method was successfully applied for determination of caffeine, SB and PS in sports and energy drinks.