Purpose <p>To evaluate the feasibility of applying a barium enema-style bowel preparation protocol to CT colonography (CTC) in clinical practice.</p> Materials and methods <p>11 patients underwent CTC using a simplified bowel preparation protocol based on magnesium citrate, similar to that used for barium enema. Two radiologists assessed the homogeneity of fluid tagging, volume of residual fluid, and degree of colonic distension in six colonic segments (cecum, ascending, transverse, descending, sigmoid, rectum) in both supine and prone positions. Each parameter was rated on a 4-point Likert scale (0 = optimal, 3 = inadequate). The mean score and proportion of segments achieving a score of 0 were calculated.</p> Results <p>More than 85% of segments received a score of 0 for tagging uniformity and colonic distension, and over 90% for residual fluid. Mean scores were below 0.3 for all three parameters. These findings indicate that the preparation protocol provided sufficient colonic cleansing and distension comparable to previously reported standard protocols.</p> Conclusion <p>A simplified bowel preparation protocol adapted from barium enema practice can be effectively applied to CT colonography, achieving clinically acceptable image quality.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Transitioning barium enema preparation protocols to CT colonography in the modern imaging era

  • Daisuke Tsurumaru,
  • Yusuke Nishimuta,
  • Katsuya Nanjo,
  • Yutaro Shimomura,
  • Kousei Ishigami

摘要

Purpose

To evaluate the feasibility of applying a barium enema-style bowel preparation protocol to CT colonography (CTC) in clinical practice.

Materials and methods

11 patients underwent CTC using a simplified bowel preparation protocol based on magnesium citrate, similar to that used for barium enema. Two radiologists assessed the homogeneity of fluid tagging, volume of residual fluid, and degree of colonic distension in six colonic segments (cecum, ascending, transverse, descending, sigmoid, rectum) in both supine and prone positions. Each parameter was rated on a 4-point Likert scale (0 = optimal, 3 = inadequate). The mean score and proportion of segments achieving a score of 0 were calculated.

Results

More than 85% of segments received a score of 0 for tagging uniformity and colonic distension, and over 90% for residual fluid. Mean scores were below 0.3 for all three parameters. These findings indicate that the preparation protocol provided sufficient colonic cleansing and distension comparable to previously reported standard protocols.

Conclusion

A simplified bowel preparation protocol adapted from barium enema practice can be effectively applied to CT colonography, achieving clinically acceptable image quality.