<p>Magnetoencephalography (MEG) delivers high spatial resolution and superior detection performance for high-frequency signals compared to Electroencephalography (EEG). Therefore, researchers can leverage MEG for high-frequency steady-state asymmetric visual evoked potential (SSaVEP). Current SSaVEP encoding typically uses low-frequency stimulation with relatively large stimulus areas, hindering the applicability of this encoding method in user-friendly brain-computer interface (BCI) systems. This study introduces an ultra critical flicker frequency (ultra-CFF) single-frequency-SDMA steady-state asymmetric visual evoked field (SSaVEF) encoding powered by MEG and presents an eight-command SSaVEF-BCI system. The BCI system features a 60&#xa0;Hz SSVEF visual stimulus landmark and eight visual targets spaced 45° apart. Ten participants took part in the offline experiments, during which data from 41 channels in the occipital region were collected. This study analyzed the spatiotemporal characteristics, frequency-space characteristics, signal-to-noise ratio, and other features of the SSaVEF signals. We also evaluated the system’s performance using the multi-DCPM algorithm. Using the multi-DCPM algorithm, the system achieved an impressive average classification accuracy of 81.65% with 4-s length data. With a data length of 1&#xa0;s, the system achieved an average Information Transfer Rate (ITR) of 32.05&#xa0;bits/min, with the highest individual ITR reached an astonishing 64.45&#xa0;bits/min. This study represents the exploration of a high-frequency spatial encoding SSVEF-BCI system based on MEG. The results demonstrate MEG’s feasibility and potential of applying MEG in such BCI systems, providing both theoretical and practical value for the further development and implementation of future BCI systems.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

A user-friendly BCI encoding by high frequency single-frequency-SDMA SSaVEF using MEG

  • Dengpei Ji,
  • Haiqing Yu,
  • Xiaolin Xiao,
  • Yongzhi Huang,
  • Xiaoyu Zhou,
  • Minpeng Xu,
  • Tzyy-Ping Jung,
  • Dong Ming

摘要

Magnetoencephalography (MEG) delivers high spatial resolution and superior detection performance for high-frequency signals compared to Electroencephalography (EEG). Therefore, researchers can leverage MEG for high-frequency steady-state asymmetric visual evoked potential (SSaVEP). Current SSaVEP encoding typically uses low-frequency stimulation with relatively large stimulus areas, hindering the applicability of this encoding method in user-friendly brain-computer interface (BCI) systems. This study introduces an ultra critical flicker frequency (ultra-CFF) single-frequency-SDMA steady-state asymmetric visual evoked field (SSaVEF) encoding powered by MEG and presents an eight-command SSaVEF-BCI system. The BCI system features a 60 Hz SSVEF visual stimulus landmark and eight visual targets spaced 45° apart. Ten participants took part in the offline experiments, during which data from 41 channels in the occipital region were collected. This study analyzed the spatiotemporal characteristics, frequency-space characteristics, signal-to-noise ratio, and other features of the SSaVEF signals. We also evaluated the system’s performance using the multi-DCPM algorithm. Using the multi-DCPM algorithm, the system achieved an impressive average classification accuracy of 81.65% with 4-s length data. With a data length of 1 s, the system achieved an average Information Transfer Rate (ITR) of 32.05 bits/min, with the highest individual ITR reached an astonishing 64.45 bits/min. This study represents the exploration of a high-frequency spatial encoding SSVEF-BCI system based on MEG. The results demonstrate MEG’s feasibility and potential of applying MEG in such BCI systems, providing both theoretical and practical value for the further development and implementation of future BCI systems.