错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Automated thermographic detection of blood vessels for DIEP flap reconstructive surgery

  • Edgar Cardenas De La Hoz,
  • Jan Verstockt,
  • Simon Verspeek,
  • Warre Clarys,
  • Filip E. F. Thiessen,
  • Thierry Tondu,
  • Wiebren A. A. Tjalma,
  • Gunther Steenackers,
  • Steve Vanlanduit

摘要

Purpose

Inadequate perfusion is the most common cause of partial flap loss in tissue transfer for post-mastectomy breast reconstruction. The current state-of-the-art uses computed tomography angiography (CTA) to locate the best perforators. Unfortunately, these techniques are expensive and time-consuming and not performed during surgery. Dynamic infrared thermography (DIRT) can offer a solution for these disadvantages.

Methods

The research presented couples thermographic examination during DIEP flap breast reconstruction with automatic segmentation approach using a convolutional neural network. Traditional segmentation techniques and annotations by surgeons are used to create automatic labels for the training.

Results

The network used for image annotation is able to label in real-time on minimal hardware and the labels created can be used to locate and quantify perforator candidates for selection with a dice score accuracy of 0.8 after 2 min and 0.9 after 4 min.

Conclusions

These results allow for a computational system that can be used in place during surgery to improve surgical success. The ability to track and measure perforators and their perfused area allows for less subjective results and helps the surgeon to select the most suitable perforator for DIEP flap breast reconstruction.