<p>In this study, a MXene-based electromagnetic absorber with a simple design at terahertz frequencies is proposed. An absorber that has a MXene layer drilled into with square and circular cavities and a thin aluminum layer as a reflector was examined. With the proper design of the structure dimensions, a MXene-based refractive index sensor with a dual-band at THz frequency and <InlineEquation ID="IEq1"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="11468_2025_2791_Article_IEq1.gif" Format="GIF" Height="16" Rendition="HTML" Resolution="72" Type="Linedraw" Width="51" /> </InlineMediaObject> <EquationSource Format="TEX">\(99.93\%\)</EquationSource> <EquationSource Format="MATHML"><math> <mrow> <mn>99.93</mn> <mo>%</mo> </mrow> </math></EquationSource> </InlineEquation> and <InlineEquation ID="IEq2"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="11468_2025_2791_Article_IEq2.gif" Format="GIF" Height="16" Rendition="HTML" Resolution="72" Type="Linedraw" Width="51" /> </InlineMediaObject> <EquationSource Format="TEX">\(97.85\%\)</EquationSource> <EquationSource Format="MATHML"><math> <mrow> <mn>97.85</mn> <mo>%</mo> </mrow> </math></EquationSource> </InlineEquation> absorption levels were obtained. The proposed design achieved 1983 and 1935 <i>Q</i>-factor values at frequencies of 0.446 THz and 0.583 THz, respectively. The proposed sensor with fractional bandwidth of <InlineEquation ID="IEq3"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="11468_2025_2791_Article_IEq3.gif" Format="GIF" Height="16" Rendition="HTML" Resolution="72" Type="Linedraw" Width="51" /> </InlineMediaObject> <EquationSource Format="TEX">\(0.050\%\)</EquationSource> <EquationSource Format="MATHML"><math> <mrow> <mn>0.050</mn> <mo>%</mo> </mrow> </math></EquationSource> </InlineEquation> and <InlineEquation ID="IEq4"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="11468_2025_2791_Article_IEq4.gif" Format="GIF" Height="16" Rendition="HTML" Resolution="72" Type="Linedraw" Width="51" /> </InlineMediaObject> <EquationSource Format="TEX">\(0.052\%\)</EquationSource> <EquationSource Format="MATHML"><math> <mrow> <mn>0.052</mn> <mo>%</mo> </mrow> </math></EquationSource> </InlineEquation> has sensitivity values of 686.2 and 557.6 (GHz/RIU). The figure of merit of the proposed sensor is calculated as 3049.8 and 1852.5 (1/RIU), and the proposed sensor is compared with sensor available in the literature. Since the designed absorber can detect refractive index changes, it also has potential applications in the identification of biological samples.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

MXene-Based Perfect Absorber Design and Refractive Index Sensing Performance

  • Huseyin Korkmaz

摘要

In this study, a MXene-based electromagnetic absorber with a simple design at terahertz frequencies is proposed. An absorber that has a MXene layer drilled into with square and circular cavities and a thin aluminum layer as a reflector was examined. With the proper design of the structure dimensions, a MXene-based refractive index sensor with a dual-band at THz frequency and \(99.93\%\) 99.93 % and \(97.85\%\) 97.85 % absorption levels were obtained. The proposed design achieved 1983 and 1935 Q-factor values at frequencies of 0.446 THz and 0.583 THz, respectively. The proposed sensor with fractional bandwidth of \(0.050\%\) 0.050 % and \(0.052\%\) 0.052 % has sensitivity values of 686.2 and 557.6 (GHz/RIU). The figure of merit of the proposed sensor is calculated as 3049.8 and 1852.5 (1/RIU), and the proposed sensor is compared with sensor available in the literature. Since the designed absorber can detect refractive index changes, it also has potential applications in the identification of biological samples.