Detector performance of the Gamma-ray Transient Monitor onboard DRO-A satellite

  • Pei-Yi Feng,
  • Zheng-Hua An,
  • Da-Li Zhang,
  • Chen-Wei Wang,
  • Chao Zheng,
  • Sheng Yang,
  • Shao-Lin Xiong,
  • Jia-Cong Liu,
  • Xin-Qiao Li,
  • Ke Gong,
  • Xiao-Jing Liu,
  • Min Gao,
  • Xiang-Yang Wen,
  • Ya-Qing Liu,
  • Xiao-Yun Zhao,
  • Fan Zhang,
  • Xi-Lei Sun,
  • Hong Lu

摘要

The Gamma-ray Transient Monitor (GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A (DRO-A) satellite with the scientific objective of detecting gamma-ray transients ranging from 20 keV to 1 MeV. The GTM was equipped with five Gamma-ray Transient Probe (GTP) detector modules utilizing a NaI(Tl) scintillator coupled with a SiPM array. To reduce the SiPM noise, GTP uses a dedicated dual-channel coincident readout design. In this work, we first studied the impact of different coincidence times on the detection efficiency and ultimately selected a 0.5 µs time coincidence window for offline data processing. To test the performance of the GTPs and validate the Monte-Carlo-simulated energy response, we conducted comprehensive ground calibration tests using the Hard X-ray Calibration Facility (HXCF) and radioactive sources, including the energy response, detection efficiency, spatial response, bias-voltage response, and temperature dependence. We extensively present the ground calibration results and validate the design and mass model of the GTP detector, thus providing the foundation for in-flight observations and scientific data analysis.