<p>Podiatrists often perform intricate procedures, such as diabetic foot debridement, onychomycosis treatment, and custom insole fabrication, which expose them to inhalation hazards like fine dust and bioaerosols generated during nail and tissue grinding. This study conducted measurements of PM<sub>4</sub> (particulate matter with an aerodynamic diameter less than 4&#xa0;µm) and bioaerosols in five podiatry clinics and three office working areas. The NIOSH Method 600 was used for PM<sub>4</sub> sampling, while NIOSH Method 800 was employed for bioaerosol sampling in these environments. Pulmonary Function Tests (PFT) were administered to 23 podiatrists and 19 office workers. Podiatrists were found to face significantly higher exposure risks to particulate matter and bioaerosols compared to office workers. This is the first study to integrate pulmonary function tests, indoor ambient bioaerosol, and particulate matter measurements in podiatry clinics. PM<sub>4</sub> levels exceeded those in office environments by 3–5 times, while bioaerosol levels were 3–4 times higher. Among the podiatry clinics, the lowest bacterial concentration in summer and the lowest fungal concentration in winter were observed in the clinic equipped with only one aspirator system. PFT analysis revealed notable differences between podiatrists and office workers with similar smoking habits. A negative correlation was identified between PFT results and bacterial and PM<sub>4</sub> concentrations in the workplace environment, indicating that as PM<sub>4</sub> and bacterial concentrations increased, certain PFT spirometry tests decreased (DLCO, FEF<sub>25-75</sub>, FEV<sub>1</sub>, FVC). Taken together, these findings suggest that the presence of bioaerosols and PM<sub>4</sub> in the workplace may impact employee health. Utilizing aspirator systems and low-speed debridement equipment in podiatry clinics may positively influence PFT results. Further studies may be warranted to explore the significant decline in PFTs among young podiatrists, with smoking habits similar to those of office workers.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Combined Assessment of Particulate Matter, Bioaerosols, and Pulmonary Function Tests for Evaluating Occupational Risks in Podiatrists

  • Serap Arsal Yıldırım,
  • Beyhan Pekey,
  • Levent Aydın,
  • Ayfer Peker Karatoprak,
  • Fetiye Kolaylı,
  • Serap Argun Barış,
  • Doğanhan Kadir Er,
  • Eda Yazıcı Özçelik,
  • Kozet Yapsakli

摘要

Podiatrists often perform intricate procedures, such as diabetic foot debridement, onychomycosis treatment, and custom insole fabrication, which expose them to inhalation hazards like fine dust and bioaerosols generated during nail and tissue grinding. This study conducted measurements of PM4 (particulate matter with an aerodynamic diameter less than 4 µm) and bioaerosols in five podiatry clinics and three office working areas. The NIOSH Method 600 was used for PM4 sampling, while NIOSH Method 800 was employed for bioaerosol sampling in these environments. Pulmonary Function Tests (PFT) were administered to 23 podiatrists and 19 office workers. Podiatrists were found to face significantly higher exposure risks to particulate matter and bioaerosols compared to office workers. This is the first study to integrate pulmonary function tests, indoor ambient bioaerosol, and particulate matter measurements in podiatry clinics. PM4 levels exceeded those in office environments by 3–5 times, while bioaerosol levels were 3–4 times higher. Among the podiatry clinics, the lowest bacterial concentration in summer and the lowest fungal concentration in winter were observed in the clinic equipped with only one aspirator system. PFT analysis revealed notable differences between podiatrists and office workers with similar smoking habits. A negative correlation was identified between PFT results and bacterial and PM4 concentrations in the workplace environment, indicating that as PM4 and bacterial concentrations increased, certain PFT spirometry tests decreased (DLCO, FEF25-75, FEV1, FVC). Taken together, these findings suggest that the presence of bioaerosols and PM4 in the workplace may impact employee health. Utilizing aspirator systems and low-speed debridement equipment in podiatry clinics may positively influence PFT results. Further studies may be warranted to explore the significant decline in PFTs among young podiatrists, with smoking habits similar to those of office workers.