<p>With the advent of modern medicine, the speed of treatment is of paramount importance. Interconnection of medical equipment allows faster testing and reporting and allows patients and doctors to view reports from anywhere in the world. To facilitate this interconnection, the DICOM standard was proposed in 1985, to handle medical images in an efficient and effective way. However, there is now a need for these machines to be connected to the internet, and this has bought about many new threats to the security of medical data. In the last five years, a large number of cybersecurity incidents have occurred in the medical field targeting DICOM images. Since the DICOM standard does not enforce security, a framework which improves the confidentiality, authentication, and integrity for the header and pixel data during transmission, through cryptographic, watermarking and anonymization techniques is proposed in this literature. The cryptographic techniques use AES in Galois/Counter Mode (GCM), and the hashes for watermarking are generated using SHA. To protect the patients’ privacy and reliability in diagnosis and treatment, the security triad CIA has been ensured in the proposed work through anonymization, hashing, encryption, timely access, and backup. It is observed that the time difference between SHA3 and SHA2 hashing are almost negligible (&lt; 2% in worst case), when smaller workloads are performed with the modern architectures. And it is always better to prefer SHA3 when hardware acceleration is available (&lt; 0.4% in worst case) for processing. The anonymization techniques allow DICOM image metadata to be stripped from the files in case they are to be published publicly. Overall, the proposed framework offers a robust solution to mitigate cybersecurity risks associated with DICOM image transmission, ensuring the confidentiality, authentication, and integrity of medical data in transit. By comparing with the other existing methods, it is noted that the proposed method achieves a structured similarity index of 0.9999 and the peak-signal-to-noise ratio of 79.58.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

An enhanced security framework for secured transfer of DICOM images by ensuring the CIA triad

  • Prateek Sharma,
  • Sneha Prem Kiron,
  • D. Aju,
  • Anisha M. Lal

摘要

With the advent of modern medicine, the speed of treatment is of paramount importance. Interconnection of medical equipment allows faster testing and reporting and allows patients and doctors to view reports from anywhere in the world. To facilitate this interconnection, the DICOM standard was proposed in 1985, to handle medical images in an efficient and effective way. However, there is now a need for these machines to be connected to the internet, and this has bought about many new threats to the security of medical data. In the last five years, a large number of cybersecurity incidents have occurred in the medical field targeting DICOM images. Since the DICOM standard does not enforce security, a framework which improves the confidentiality, authentication, and integrity for the header and pixel data during transmission, through cryptographic, watermarking and anonymization techniques is proposed in this literature. The cryptographic techniques use AES in Galois/Counter Mode (GCM), and the hashes for watermarking are generated using SHA. To protect the patients’ privacy and reliability in diagnosis and treatment, the security triad CIA has been ensured in the proposed work through anonymization, hashing, encryption, timely access, and backup. It is observed that the time difference between SHA3 and SHA2 hashing are almost negligible (< 2% in worst case), when smaller workloads are performed with the modern architectures. And it is always better to prefer SHA3 when hardware acceleration is available (< 0.4% in worst case) for processing. The anonymization techniques allow DICOM image metadata to be stripped from the files in case they are to be published publicly. Overall, the proposed framework offers a robust solution to mitigate cybersecurity risks associated with DICOM image transmission, ensuring the confidentiality, authentication, and integrity of medical data in transit. By comparing with the other existing methods, it is noted that the proposed method achieves a structured similarity index of 0.9999 and the peak-signal-to-noise ratio of 79.58.