<p>Dose estimation using unconventional dosimeters during radiological/nuclear emergencies remains challenging and essential for medical triage. In this work, we have explored the potential of utilizing eggshells as an unconventional dosimeter using electron spin resonance (ESR) spectroscopy. Eggshell particle size was optimized (210 to 250&#xa0;µm) to remove the angular dependence of ESR signal using a Goniometer setup. The radiation induced radicals in irradiated eggshells were identified as orthorhombic <InlineEquation ID="IEq1"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10967_2024_9962_Article_IEq1.gif" Format="GIF" Height="20" Rendition="HTML" Resolution="72" Type="Linedraw" Width="37" /> </InlineMediaObject> <EquationSource Format="TEX">\({\text{CO}}_{2}^{-}\)</EquationSource> <EquationSource Format="MATHML"><math> <msubsup> <mtext>CO</mtext> <mrow> <mn>2</mn> </mrow> <mo>-</mo> </msubsup> </math></EquationSource> </InlineEquation>, axial <InlineEquation ID="IEq2"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10967_2024_9962_Article_IEq2.gif" Format="GIF" Height="20" Rendition="HTML" Resolution="72" Type="Linedraw" Width="37" /> </InlineMediaObject> <EquationSource Format="TEX">\({\text{CO}}_{2}^{-}\)</EquationSource> <EquationSource Format="MATHML"><math> <msubsup> <mtext>CO</mtext> <mrow> <mn>2</mn> </mrow> <mo>-</mo> </msubsup> </math></EquationSource> </InlineEquation>, and axial <InlineEquation ID="IEq3"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10967_2024_9962_Article_IEq3.gif" Format="GIF" Height="21" Rendition="HTML" Resolution="72" Type="Linedraw" Width="43" /> </InlineMediaObject> <EquationSource Format="TEX">\({\text{CO}}_{3}^{3-}\)</EquationSource> <EquationSource Format="MATHML"><math> <msubsup> <mtext>CO</mtext> <mrow> <mn>3</mn> </mrow> <mrow> <mn>3</mn> <mo>-</mo> </mrow> </msubsup> </math></EquationSource> </InlineEquation> radicals. Among them, <InlineEquation ID="IEq4"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10967_2024_9962_Article_IEq4.gif" Format="GIF" Height="17" Rendition="HTML" Resolution="72" Type="Linedraw" Width="86" /> </InlineMediaObject> <EquationSource Format="TEX">\({\text{g}}_{\perp }=2.0020\)</EquationSource> <EquationSource Format="MATHML"><math> <mrow> <msub> <mtext>g</mtext> <mo>⊥</mo> </msub> <mo>=</mo> <mn>2.0020</mn> </mrow> </math></EquationSource> </InlineEquation> component of axial <InlineEquation ID="IEq5"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10967_2024_9962_Article_IEq5.gif" Format="GIF" Height="20" Rendition="HTML" Resolution="72" Type="Linedraw" Width="37" /> </InlineMediaObject> <EquationSource Format="TEX">\({\text{CO}}_{2}^{-}\)</EquationSource> <EquationSource Format="MATHML"><math> <msubsup> <mtext>CO</mtext> <mrow> <mn>2</mn> </mrow> <mo>-</mo> </msubsup> </math></EquationSource> </InlineEquation> radical and <InlineEquation ID="IEq6"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10967_2024_9962_Article_IEq6.gif" Format="GIF" Height="20" Rendition="HTML" Resolution="72" Type="Linedraw" Width="82" /> </InlineMediaObject> <EquationSource Format="TEX">\({\text{g}}_{\parallel }=2.0011\)</EquationSource> <EquationSource Format="MATHML"><math> <mrow> <msub> <mtext>g</mtext> <mo stretchy="false">‖</mo> </msub> <mo>=</mo> <mn>2.0011</mn> </mrow> </math></EquationSource> </InlineEquation> component of axial <InlineEquation ID="IEq7"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10967_2024_9962_Article_IEq7.gif" Format="GIF" Height="21" Rendition="HTML" Resolution="72" Type="Linedraw" Width="43" /> </InlineMediaObject> <EquationSource Format="TEX">\({\text{CO}}_{3}^{3-}\)</EquationSource> <EquationSource Format="MATHML"><math> <msubsup> <mtext>CO</mtext> <mrow> <mn>3</mn> </mrow> <mrow> <mn>3</mn> <mo>-</mo> </mrow> </msubsup> </math></EquationSource> </InlineEquation> radical were used for dosimetry studies. Dose response was found to be linear up to 1&#xa0;kGy with a minimum detectable dose of ~ 1&#xa0;Gy. From fading studies, the signal was found to decay up to 55% within eight days due to ~ 93% fading of axial <InlineEquation ID="IEq8"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10967_2024_9962_Article_IEq8.gif" Format="GIF" Height="21" Rendition="HTML" Resolution="72" Type="Linedraw" Width="43" /> </InlineMediaObject> <EquationSource Format="TEX">\({\text{CO}}_{3}^{3-}\)</EquationSource> <EquationSource Format="MATHML"><math> <msubsup> <mtext>CO</mtext> <mrow> <mn>3</mn> </mrow> <mrow> <mn>3</mn> <mo>-</mo> </mrow> </msubsup> </math></EquationSource> </InlineEquation> radicals. Single aliquot additive dose (SAAD) technique was used for dose reconstruction from irradiated eggshells, and the technique was validated with other standard dosimeters like alanine/ESR and TL (thermoluminescence) discs. The results of the detailed dosimetric investigations showed that eggshells can be potentially used for retrospective dose assessment in case of radiation emergencies by applying proper fading correction.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Chicken eggshells as unconventional ESR dosimeters: insight into the influence of particle size and fading characteristic

  • Madhusmita Panda,
  • S. Jakathamani,
  • O. Annalakshmi,
  • Shailesh Joshi,
  • M. T. Jose,
  • C. V. Srinivas,
  • B. Venkatraman

摘要

Dose estimation using unconventional dosimeters during radiological/nuclear emergencies remains challenging and essential for medical triage. In this work, we have explored the potential of utilizing eggshells as an unconventional dosimeter using electron spin resonance (ESR) spectroscopy. Eggshell particle size was optimized (210 to 250 µm) to remove the angular dependence of ESR signal using a Goniometer setup. The radiation induced radicals in irradiated eggshells were identified as orthorhombic \({\text{CO}}_{2}^{-}\) CO 2 - , axial \({\text{CO}}_{2}^{-}\) CO 2 - , and axial \({\text{CO}}_{3}^{3-}\) CO 3 3 - radicals. Among them, \({\text{g}}_{\perp }=2.0020\) g = 2.0020 component of axial \({\text{CO}}_{2}^{-}\) CO 2 - radical and \({\text{g}}_{\parallel }=2.0011\) g = 2.0011 component of axial \({\text{CO}}_{3}^{3-}\) CO 3 3 - radical were used for dosimetry studies. Dose response was found to be linear up to 1 kGy with a minimum detectable dose of ~ 1 Gy. From fading studies, the signal was found to decay up to 55% within eight days due to ~ 93% fading of axial \({\text{CO}}_{3}^{3-}\) CO 3 3 - radicals. Single aliquot additive dose (SAAD) technique was used for dose reconstruction from irradiated eggshells, and the technique was validated with other standard dosimeters like alanine/ESR and TL (thermoluminescence) discs. The results of the detailed dosimetric investigations showed that eggshells can be potentially used for retrospective dose assessment in case of radiation emergencies by applying proper fading correction.