<p>Radioisotopes of actinium are valuable because of their potential use in the medical industry. Actinium-225 shows promise for treating disease—like cancer—via targeted alpha therapy (TAT), and the longer-lived actinium-227 is the parent of two radionuclides with potential application in TAT radiopharmaceuticals, thorium-227 and radium-223. Continuing progress in the development of these medical applications requires robust and diverse methods for extracting and purifying actinium from a wide range of matrices. To define the strengths and limitations of separation methods commonly employed in actinium processing, we characterized the performance of ion exchange and extraction chromatographic steps for removing contaminants found in stainless steel (chromium, iron, nickel, and silicon) and aluminum from actinium-227. While AG-MP1 anion exchange resin with HCl<sub>(<i>aq</i>)</sub> successfully removed iron, cation exchanger AG 50W-X8 removed most other contaminants. The most persistent contaminant was aluminum, which was removed using a DGA Normal extraction resin. These results are presented within the context of applying that methodology toward actinium purification strategies.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Actinium purification from elemental components of stainless steel and aluminum

  • Jan Klouda,
  • Sara L. Adelman,
  • Kelly E. Aldrich,
  • Stosh A. Kozimor,
  • Mila Nhu Lam,
  • Laura M. Lilley,
  • Veronika Mocko,
  • Sara L. Thiemann

摘要

Radioisotopes of actinium are valuable because of their potential use in the medical industry. Actinium-225 shows promise for treating disease—like cancer—via targeted alpha therapy (TAT), and the longer-lived actinium-227 is the parent of two radionuclides with potential application in TAT radiopharmaceuticals, thorium-227 and radium-223. Continuing progress in the development of these medical applications requires robust and diverse methods for extracting and purifying actinium from a wide range of matrices. To define the strengths and limitations of separation methods commonly employed in actinium processing, we characterized the performance of ion exchange and extraction chromatographic steps for removing contaminants found in stainless steel (chromium, iron, nickel, and silicon) and aluminum from actinium-227. While AG-MP1 anion exchange resin with HCl(aq) successfully removed iron, cation exchanger AG 50W-X8 removed most other contaminants. The most persistent contaminant was aluminum, which was removed using a DGA Normal extraction resin. These results are presented within the context of applying that methodology toward actinium purification strategies.