错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Estimation of background radiation in the indoor air in geo-sensitive zones of the Garhwal Himalaya, India

  • Ganesh Prasad,
  • Krishna Pal Singh,
  • Sanjeev Kimothi,
  • Subhash Chandra,
  • R. C. Ramola

摘要

The study assesses environmental background radiation from radon, thoron, and thoron decay products across distinct geological settings in the Garhwal Himalaya region by using RADUET, CR-39 plastic track detectors, and deposition-based thoron (220Rn)progeny detectors. The measurements were conducted indoors throughout the winter, summer, and rainfall seasons during the year 2013. The annual inhalation doses from 220Rn progenies ranged between 0.83 and 2.99 mSv y−1, averaging 1.94 mSv y−1. The annual effective dose (AED), reflecting biological radiation impact, varied from 0.58 to 2.78 mSv y−1, with an average of 1.75 mSv y−1.