错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Low-level tritium measurements in freshwater and seawater samples

  • Małgorzata Dymecka,
  • Grzegorz Szaciłowski,
  • Katarzyna Rzemek,
  • Jakub Ośko

摘要

The aim of this study was to test two potential tritium determination methods (with and without electrolysis enrichment) suitable for low-level measurements. Both methodologies were applied to water samples from the Baltic Sea and ten Polish rivers providing new data on tritium activity concentration. Optimization steps carried out to the standard method lowered minimum detectable activity concentration (MDC) from 3.1 to 1.8 Bq L–1 (at 95% confidence level) enabling to apply it to environmental water samples. However, electrolytic enrichment method of MDC of 0.20 Bq L–1 provided more accurate results for tritium activity concentration in surface waters.