<p>Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100&#xa0;eV is crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a <InlineEquation ID="IEq1"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10909_2025_3330_Article_IEq1.gif" Format="GIF" Height="10" Rendition="HTML" Resolution="72" Type="Linedraw" Width="13" /> </InlineMediaObject> <EquationSource Format="TEX">\(^{55}\)</EquationSource> <EquationSource Format="MATHML"><math> <mmultiscripts> <mrow /> <mrow /> <mn>55</mn> </mmultiscripts> </math></EquationSource> </InlineEquation>Fe source to irradiate a two-staged target arrangement, emitting characteristic emission lines from 677&#xa0;eV to 6.5&#xa0;keV. We demonstrate the potential of this new XRF source to calibrate a 0.75&#xa0;g CaWO<InlineEquation ID="IEq2"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10909_2025_3330_Article_IEq2.gif" Format="GIF" Height="10" Rendition="HTML" Resolution="72" Type="Linedraw" Width="8" /> </InlineMediaObject> <EquationSource Format="TEX">\(_4\)</EquationSource> <EquationSource Format="MATHML"><math> <mmultiscripts> <mrow /> <mn>4</mn> <mrow /> </mmultiscripts> </math></EquationSource> </InlineEquation> crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in macro-calorimeters based on transition edge sensors (TES).</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Sub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters Using a Novel X-ray Fluorescence Source

  • H. Abele,
  • G. Angloher,
  • B. Arnold,
  • M. Atzori Corona,
  • A. Bento,
  • E. Bossio,
  • J. Burkhart,
  • F. Cappella,
  • M. Cappelli,
  • N. Casali,
  • R. Cerulli,
  • A. Cruciani,
  • G. Del Castello,
  • M. del Gallo Roccagiovine,
  • S. Dorer,
  • A. Erhart,
  • M. Friedl,
  • S. Fichtinger,
  • V. M. Ghete,
  • M. Giammei,
  • C. Goupy,
  • D. Hauff,
  • F. Jeanneau,
  • E. Jericha,
  • M. Kaznacheeva,
  • A. Kinast,
  • H. Kluck,
  • A. Langenkämper,
  • T. Lasserre,
  • D. Lhuillier,
  • M. Mancuso,
  • R. Martin,
  • B. Mauri,
  • A. Mazzolari,
  • L. McCallin,
  • H. Neyrial,
  • C. Nones,
  • L. Oberauer,
  • T. Ortmann,
  • L. Pattavina,
  • L. Peters,
  • F. Petricca,
  • W. Potzel,
  • F. Pröbst,
  • F. Pucci,
  • F. Reindl,
  • M. Romagnoni,
  • J. Rothe,
  • N. Schermer,
  • J. Schieck,
  • S. Schönert,
  • C. Schwertner,
  • L. Scola,
  • G. Soum-Sidikov,
  • L. Stodolsky,
  • R. Strauss,
  • M. Tamisari,
  • R. Thalmeier,
  • C. Tomei,
  • M. Vignati,
  • M. Vivier,
  • A. Wex,
  • K. V. Mirbach,
  • V. Wagner

摘要

Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100 eV is crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a \(^{55}\) 55 Fe source to irradiate a two-staged target arrangement, emitting characteristic emission lines from 677 eV to 6.5 keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 g CaWO \(_4\) 4 crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in macro-calorimeters based on transition edge sensors (TES).