<p>The static magnetic properties of the silica-based aerogels of Cryogel® and Pyrogel®, manufactured by Aspen Aerogels®, were measured over a range of temperatures (<InlineEquation ID="IEq1"> <InlineMediaObject> <ImageObject Color="BlackWhite" FileRef="10909_2025_3317_Article_IEq1.gif" Format="GIF" Height="16" Rendition="HTML" Resolution="72" Type="Linedraw" Width="122" /> </InlineMediaObject> <EquationSource Format="TEX">\(2\,\textrm{K} \le T \le 400\,\textrm{K}\)</EquationSource> <EquationSource Format="MATHML"><math> <mrow> <mn>2</mn> <mspace width="0.166667em" /> <mtext>K</mtext> <mo>≤</mo> <mi>T</mi> <mo>≤</mo> <mn>400</mn> <mspace width="0.166667em" /> <mtext>K</mtext> </mrow> </math></EquationSource> </InlineEquation>) and in magnetic fields up to 70&#xa0;kG. These data and a model of the responses are reported, so these properties are familiar to others who may benefit from knowing them before the materials are employed in potential applications.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Static Magnetic Properties of Cryogel® and Pyrogel® at Low Temperatures and in High Magnetic Fields

  • Caeli L. Benyacko,
  • Garrett T. Hauser,
  • Raven J. Rawson,
  • Alan J. Sherman,
  • Quinton L. Wiebe,
  • Krittin Poottafai,
  • Daniel R. Talham,
  • Mark W. Meisel

摘要

The static magnetic properties of the silica-based aerogels of Cryogel® and Pyrogel®, manufactured by Aspen Aerogels®, were measured over a range of temperatures ( \(2\,\textrm{K} \le T \le 400\,\textrm{K}\) 2 K T 400 K ) and in magnetic fields up to 70 kG. These data and a model of the responses are reported, so these properties are familiar to others who may benefit from knowing them before the materials are employed in potential applications.