摘要

Neutrino mass estimation experiments and cosmic microwave background (CMB) radiation surveys both employ low-temperature detectors (LTD) known as calorimeters and bolometers, respectively. These detectors operate typically between 10 and 300 mK. LTDs multiplexed by means of a microwave superconducting quantum interference device multiplexer (µMUX) demonstrated to be an excellent device for the readout of several detectors in the microwave region. This entails generating a multi-tonal signal and its subsequent readout. A single-tone detection method based on a Goertzel filter bank (GFB) channelizer was used for the readout of the aforementioned signal, implemented in a software-defined radio readout architecture within a field-programmable gate array. The measurements presented here demonstrate remarkable results in validating the suitability of the GFB channelizer for this system.