<p>Ratiometric fluorescent probes have irreplaceable advantages of traditional single fluorescent probes, such as high accuracy, low background interference and high signal-to-noise ratio, which have attracted extensive attention but the preparation process is still a challengment. In this paper, fluorescent carbon dots (CDs) was prepared by hydrothermal treatment of citric acid and triethylamine, and electrostatic adsorption with Rhodamine, which was used to construct ratiometric fluorescent nanoprobes (WZ-L). Among them, rhodamine B was used as the reference signal of the fluorescent probe, which could eliminate part of the error. Carbon dots (CDs) were used as the identification signal for the detection of Hg<sup>2+</sup>. The probe specifically recognized Hg<sup>2+</sup> in a wide pH range and had a well linear range (0-100 µL), which can be used for the quantitative detection of real Chinese herbal medicine samples. including Codonopsis and Codonopsis. In particular, the probe could provide a rapid response to Hg<sup>2+</sup> within 2&#xa0;min with a detection limit as low as 7.94 µM. It is shown that this probe has a large application potential for future quantitative detection of Hg<sup>2+</sup> in real samples, which provides a new analytical method and strategy for the subsequent detection of heavy metal ions.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

A Novel Ratiometric Fluorescent Probe Based on Carbon Dots and Rhodamine for Rapid Detection of Hg2+ in Herbal Medicines and Rivers

  • Qian Wang,
  • Qian Zhang,
  • Jiayi Zhang,
  • Jiayi Li,
  • Mengpei Xie,
  • Mengyi Shen,
  • Yuping Tang,
  • Weifang Luo

摘要

Ratiometric fluorescent probes have irreplaceable advantages of traditional single fluorescent probes, such as high accuracy, low background interference and high signal-to-noise ratio, which have attracted extensive attention but the preparation process is still a challengment. In this paper, fluorescent carbon dots (CDs) was prepared by hydrothermal treatment of citric acid and triethylamine, and electrostatic adsorption with Rhodamine, which was used to construct ratiometric fluorescent nanoprobes (WZ-L). Among them, rhodamine B was used as the reference signal of the fluorescent probe, which could eliminate part of the error. Carbon dots (CDs) were used as the identification signal for the detection of Hg2+. The probe specifically recognized Hg2+ in a wide pH range and had a well linear range (0-100 µL), which can be used for the quantitative detection of real Chinese herbal medicine samples. including Codonopsis and Codonopsis. In particular, the probe could provide a rapid response to Hg2+ within 2 min with a detection limit as low as 7.94 µM. It is shown that this probe has a large application potential for future quantitative detection of Hg2+ in real samples, which provides a new analytical method and strategy for the subsequent detection of heavy metal ions.