<p>In order to quickly and conveniently detect multiple heavy metal ions in aqueous phase simultaneously, a polyethylene glycol passivated N-doping carbon quantum (<i>p</i>-N-CQDs) was synthesized by a hydrothermal method with citric acid (carbon source), urea (nitrogen source) and polyethylene glycol (passivator). The as-prepared <i>p</i>-N-CQDs could be evenly dispersed in deionized water, and the average diameter was 1.83&#xa0;nm, resulting in 18.72% of fluorescence quantum yield. As a sensor, the fluorescence of <i>p</i>-N-CQDs would be significantly quenched with Fe<sup>3+</sup> or Cu<sup>2+</sup> under the different maximum emission wavelength of 452&#xa0;nm and 448&#xa0;nm, respectively. Therefore, a method for simultaneously detecting multiple heavy metal ions was proposed by discriminative fitting of the fluorescence emission peaks after metal ion quenching. Upon the experiments, two linear calibration curves between resolving fluorescence intensities of <i>p</i>-N-CQDs and concentration of the metal ions were obtained within a range of 10 to 1000 µM of Cu<sup>2+</sup> and 40 to 800 µM of Fe<sup>3+</sup>. And a limit of detection (LOD) of 0.032 µM was attained after resolving the curves based on the emission wavelength of 448&#xa0;nm for Cu<sup>2+</sup> and 452&#xa0;nm for Fe<sup>3+</sup> by a peak splitting software. In addition, the stability, selectivity and anti-interference of the proposal senor was confirmed.</p>

错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Facile Synthesis of Polyethylene Glycol Passivated N-doping CQDs as Fluorescent Probe for Multi-Target Simultaneous Detection in Heavy-Metals Solution

  • Guangmei Zhang,
  • Shang Feng,
  • Ruiming Ge,
  • Ying Liu,
  • Qiufeng Zhu

摘要

In order to quickly and conveniently detect multiple heavy metal ions in aqueous phase simultaneously, a polyethylene glycol passivated N-doping carbon quantum (p-N-CQDs) was synthesized by a hydrothermal method with citric acid (carbon source), urea (nitrogen source) and polyethylene glycol (passivator). The as-prepared p-N-CQDs could be evenly dispersed in deionized water, and the average diameter was 1.83 nm, resulting in 18.72% of fluorescence quantum yield. As a sensor, the fluorescence of p-N-CQDs would be significantly quenched with Fe3+ or Cu2+ under the different maximum emission wavelength of 452 nm and 448 nm, respectively. Therefore, a method for simultaneously detecting multiple heavy metal ions was proposed by discriminative fitting of the fluorescence emission peaks after metal ion quenching. Upon the experiments, two linear calibration curves between resolving fluorescence intensities of p-N-CQDs and concentration of the metal ions were obtained within a range of 10 to 1000 µM of Cu2+ and 40 to 800 µM of Fe3+. And a limit of detection (LOD) of 0.032 µM was attained after resolving the curves based on the emission wavelength of 448 nm for Cu2+ and 452 nm for Fe3+ by a peak splitting software. In addition, the stability, selectivity and anti-interference of the proposal senor was confirmed.