A Phenanthroimidazole-Based Luminophore for Selective and Specific Identification of Sarin Simulant, Diethylchlorophosphate
摘要
The simplicity of synthesis, significant toxicity of organophosphorus-containing nerve agents, and ease of use of their in-terrorism attacks highlight the necessity to create efficient probes and precise methods for detecting these chemicals. This study developed luminogenic probe 4-(1 H-phenanthrene imidazole-2-yl) benzaldehyde, PB for selectively recognizing lethal chemical sarin mimicking diethylchlorophosphate (DCP) with µM detection limit. Following the addition of DCP to the PB solution, the fluorescence changed from bluish-cyan to green simultaneously; after the insertion of triethylamine (TEA) into the PB-DCP phosphorylated solution, the fluorescence of the original one came back, and it occurred five times. A paper strip-based test kit and dip-stick experiments have been executed to demonstrate the practical applicability of our sensor PB and instant, on-site recognition of the target analyte DCP. An experiment has been investigated using a smartphone and red-green-blue (RGB) color analysis, which offers a novel way for the fast, on-site visual detection and quantification of DCP in actual samples. It also reduces equipment costs, speeds up detection times, and substantially simplifies the operation procedure.