错误:搜索内容不能为空,请输入英文关键词
错误:关键词超出字数限制,请精简
高级检索

Radiofrequency balloon ablation: 1-year outcomes of the AURORA study

  • Ilaria My,
  • Boris Schmidt,
  • Laura Rottner,
  • Shota Tohoku,
  • Marc Lemoine,
  • David Schaack,
  • Fabian Moser,
  • Lukas Urbanek,
  • Julius Obergassel,
  • Djemail Ismaili,
  • Jun Hirokami,
  • Paulus Kirchhof,
  • Karin Plank,
  • Bruno Reissmann,
  • Feifan Ouyang,
  • Andreas Rillig,
  • Julian Chun,
  • Andreas Metzner,
  • Stefano Bordignon

摘要

Background

A novel irrigated radiofrequency balloon (RFB) for pulmonary vein isolation (PVI) integrated into a 3D mapping platform was recently launched.

Methods

Patients undergoing a first atrial fibrillation (AF) ablation at two German high-volume EP centers were included into the prospective AURORA registry. All patients underwent clinical follow-up (FU) at 90, 180, and 360 days following ablation including 48-h Holter ECGs.

Results

A total of 99 patients were enrolled (43/99 (43.4%) women, median age 67 years (interquartile range [IQR] 59–74), 43/99 (43.4%) persistent AF (Pers-AF), median left ventricular ejection fraction (LVEF) 60% (IQR 62–55)). Eighty-eight patients completed the follow-up. Acute PVI was achieved in 383/383 (100%) PV. Single-shot PVI was achieved in 211/383 (55.1%) PVs. Primary adverse events occurred in 3% of patients (1 postprocedural pharyngeal bleeding, 1 myocardial infarction, 1 non-cardiovascular death); no pericardial effusion, stroke, or phrenic nerve paralysis was observed. Median ablation and procedure times were 23 (IQR 18–32) and 67 (IQR 57–85) min, respectively. Median dose area product was 761 (IQR 509–1534) mGycm2. AF-free survival after a median FU of 361 (IQR 261–375) days was 78.4% for paroxysmal AF (PAF) and 75.4% for Pers-AF (p value = 0.828). Early recurrence of atrial tachyarrhythmia at the 90-day visit was the only independent predictor for AF recurrence at 1 year upon multiple regression analysis (hazard ratio [HR] 3.198; 95% confidence interval [95% CI] 1.036–10.32, p value = 0.0433).

Conclusion

RFB-based PVI is acutely successful, appears safe, and has comparable rhythm outcomes to other single-shot AF ablation tools. A recurrence of AF at 90 days predicts later AF recurrence.

Graphical Abstract