Potential damage to ovarian reserve from laparoscopic electrocoagulation in endometriomas and benign ovarian cysts: a systematic review and meta-analysis
摘要
Laparoscopic cystectomy for ovarian endometriomas and benign ovarian cysts is often conducted through hemostatic methods, with bipolar electrocoagulation as a common approach. This study evaluated the impact of electrocoagulation, primarily through bipolar energy, versus nonthermal hemostatic methods on ovarian reserve in patients undergoing laparoscopic cystectomy for ovarian endometriomas and benign ovarian cysts.
MethodsA systematic review with meta-analysis was conducted by searching the Cochrane Library, PubMed, EMBASE, and Web of Science databases. Randomized controlled trials (RCTs) comparing the impact of nonthermal hemostatic methods and electrocoagulation on the ovarian reserve during laparoscopic cystectomy were included. The Cochrane Risk of Bias Tool for Randomized Controlled Trials (ROB 2.0) was utilized to assess the quality of the included studies. The meta-analysis included 13 RCTs involving 1043 patients. Postoperative serum anti-Müllerian hormone (AMH) levels and antral follicle counts (AFCs) were analyzed using Review Manager ver. 5.4.
ResultsCompared with the bipolar group, patients with endometriomas in the nonthermal hemostatic group exhibited significantly higher postoperative AMH levels at 1, 3, 6, and 12 months. Conversely, no significant differences in AMH levels were observed in patients with benign ovarian cysts. Similarly, AFCs showed no significant differences, except for lower postoperative AFCs in patients with endometrioma in the electrocoagulation group.
ConclusionNonthermal hemostatic methods are associated with more effective preservation of the ovarian reserve compared with bipolar electrocoagulation in laparoscopic cystectomy for ovarian endometriomas. However, no significant impact of bipolar electrocoagulation on the ovarian reserve was observed in patients with benign ovarian cysts.
Trial registrationRegistered in PROSPERO on April 10, 2023; ID # CRD42023413158.